background image

940-M-0003  

Page 1 

Revision B 

 

 
 

SPX SPARTAN  
Floodlight Range

Installation Guide 

 

CML13ATEX3007 & IEC Ex CML14.0001  

 

This installation guide provides instructions for installing the Infra-Red and White-
Light SPARTAN series of explosion protected floodlights. 

 

*Text in red is specific for emergency variants  

 

 

1.  Safety Instructions 

2.  Installation 

3.  Maintenance 

4.  Technical  Specification 

5.  Trouble Shooting 

 

Overview 

IMPORTANT INFORMATION 
 

The SPARTAN series of explosion protected bulkheads are specialist devices, certified 
for use in specific operating environments. 

The units must be installed in accordance with these instructions, must be correctly 
certified for the specific operating environment and must be installed by suitably qualified 
personnel. 

*Emergency bulkheads will require the fuse to be reconnected upon installation and the 
floodlight subjected to three 24 hour charge/discharge cycles to bring the battery up to 
peak capacity. 

If you have any queries about the installation or the certification of the unit 

– please 

contact Raytec for immediate assistance and advice.

 

 

Содержание SPARTAN SPX Series

Страница 1: ...AN series of explosion protected bulkheads are specialist devices certified for use in specific operating environments The units must be installed in accordance with these instructions must be correct...

Страница 2: ...nstructed from marine grade aluminium and toughened glass The end user must ensure that these materials are suitable for the environment the SPARTAN unit will be installed in Zone 1 and Zone 2 Hazardo...

Страница 3: ...0003 Page 3 Revision B 2 INSTALLATION Mounting SPARTAN Unit 1 To meet the requirements of certification a MINIMUM of 2 fixing points must be used the fixing points must be suitable for the conditions...

Страница 4: ...upplied without the mounting brackets fitted these can be found in a polythene bag in the main carton and should be secured to the rear of the unit before installation The bolts packaged along with th...

Страница 5: ...ed and the unit charged for 24 hours and then discharged repeated 3 times to bring the battery up to peak capacity 9 If a 4 core cable is used on emergency luminaires L Ls N and E the link cable at th...

Страница 6: ...60Hz IP Rating IP66 67 Weight std 5Kg 6Kg Dimensions See previous pages for line diagrams ATEX and IECEx Rating See below PROTECTION CERTIFICATION CML13ATEX3007 or IEC Ex CML14 0001 II 2 GD Ex em IIC...

Страница 7: ...t 50 option SPX BL24 W 120120 Spartan Bulkhead 24 LED White Light 120 option SPX BL24 W 3510 Spartan Bulkhead 24 LED White Light 35x10 SPX BL24 W 6025 Spartan Bulkhead 24 LED White Light 60x25 SPX BL2...

Страница 8: ...ane Eccleston Chester CH4 9JN Certificate numbers CML13ATEX3007 or IEC Ex CML14 0001 Quality Assurance Notification Sira Equipment Marking II 2 GD Ex em IIC T4 or T5 Gb Ta 52 o C to 55 o C or II 2 GD...

Отзывы: