25
The command codes and their meaning are described below. The upper-case
commands are shown, followed by lower case letters denoting the numeric
argument.
Note:
Any changes made using Ethernet commands are not saved permanently until
the
AW
command has been issued.
10.4
General commands
Report the version of firmware running in the VTR6
This command returns the firmware version. For example:
VR
returns
VTR6 (HW001) V001
Set switched mode
The output is set to switched mode at a percentage of full
brightness.
RW1,s
Where:
s
= setting in percent (s = 0 to 100)
Set pulse mode
The output can be set up to pulse on a trigger input. The delay from trigger to
the start of the pulse, the length of the pulse and the brightness are
configurable.
An error is generated if the brightness setting requires a current greater
than 20A or if the combination of pulse width and setting is not allowed.
RTc,p,d,s
RTc,p,d,s,r
Where:
c
=
1
to select light strobe output
c
=
2
to select a trigger output signal
p
= pulse width in milliseconds (0.01 to 3)
d
= delay from trigger to pulse in milliseconds (0.01 to 999)
s
= setting in percent (s = 0 to 100)
r
= retrigger delay in milliseconds. This parameter is optional
Содержание PULSESTAR VTR6