17. FAULT CODES
When the boiler detects a temporary fault condition, the
appropriate code is shown flashing on the display. If/when the
fault code is final, the pump will perform a 60-second post
circulation and the red LED will be illuminated.
CODE
CAUSE
ALARM TYPE
ACTION
AL10
Ignition failure/not flame sensed,
Final
Reset, check appliance operation
condense sensor activated
AL20
Limit thermostat fault, blocked flue switch,
flue thermostat
Final
Reset, check appliance operation
AL21
External device fault (UHT/CPA)
Final
Reset, check appliance
AL26
Return temperature too high
Final
Reset, check pump, ensure there is sufficient
flow sensor temperature). Circulation around
heating circuit/s
AL28
Temperature differential inverted
Final
Reset, check pump, ensure there is sufficient
(return sensor temperature higher than
circulation around heating circuit/s thermistors
flowsensor temperature)
AL29
Flue sensor over temperature lock out
Final
Reset check appliance operation
AL34
Fan blower signal fault
Final
Reset check appliance operation, check fan
AL40
Insufficient system water pressure
Final
Check/refill system pressure, reset, check
appliance operation
AL41
Insufficient system water pressure
Temporary
Check/refill system pressure, check appliance
operation
AL52
Internal fault
Final
Reset, check boiler operation
A
L55
Jumper tag fault
Final
Check jumper tag configuration
AL60
Jumper tag fault
Temporary
Check jumper tag configuration
AL71
Primary (flow) sensor fault
Temporary
Check primary thermistor, check wiring
AL73
Return sensor fault
Temporary
Check return thermistor, check /wiring
AL74
Variation on temperature of primary
Final
Reset, check boiler operation, check
and/or return too high pump, ensure there is
sufficient circulation around heating circuit/s
AL79
Flow temperature too high, or
Final
Reset, check appliance operation, check
temperature differential between
thermistors
primary and return too high
AL91
The main heat exchanger need to be
Advice
Call the Raypak technical service
cleaned
Содержание XPAK 120
Страница 1: ......
Страница 20: ...20 Fig 10 Fig 9...
Страница 21: ...21 Fig 11 Fig 12...
Страница 33: ...33 Fig 32 TWO PIPES SINGLE WALL SEALEDCOMBUSTIONOPERATION a total intake length 0 b total flue length EXHAUST...
Страница 38: ...38 WIRING FUNCTIONAL DIAGRAM Fig 40...
Страница 59: ...59 14 EXPLODED DIAGRAMS Drawing 1 5 7 9 3 12a 4 6 8 12a 1 10 2 11...
Страница 60: ...60 Drawing 2 17 18 56a 56a 14 15 56b 13 16 12b 19...