background image

7

Boiler Control and 
On-Board Diagnostic Center

Raypak’s XFyre comes equipped with a microprocessor control
center that displays its information on a 2x20 character LCD
display in plain English. All set-up and programming is done at
this interface. Control monitors boiler system status including
safeties, ignition faults and also stores up to 10 reported faults.
The diagnostic center even monitors and reports the flame
strength signal in microamps. Monitor blower speed, BMS
input and all water and air sensors. A normally-open and nor-
mally-closed dry contact alarm relay is provided.

Outdoor Proven 

Raypak is no stranger to the outdoor environment. Our touchpad is 100% waterproof and has been proven and perfected on our
pool products. No guesswork here, just one tough boiler ready to take on jobs that others have to walk away from.

Safety Faults

Condensate Full

Outdoor Sensor

Line Voltage

Blocked Vent

Low Water Level

24 Volt Low

Low Water Flow

Temper Blocking

High Temperature

Flue/Gas Pressure

Supply Thermistor

Return Thermistor

Supply High

Ignition Control Faults

No Flame

Flame Failure

Flame When Off

Fan Speed Error

X

treme Control

Example Diagnostic Fault Report

Diagnostic Information

X

treme Firing Rates

Cascade up to 8 Boilers 
Deliver up to 6.8 Million BTU at a 40:1 turndown rate!

The XFyre comes standard with a built-in Cascading Boiler Control. No other controls to buy, just daisy chain the units together
with CAT 3 or CAT 5 computer network cables 

(not supplied)

that plug into the front mounted communication bus on each unit

(see low voltage wiring box opposite page)

. Designate a Cascade Master Boiler and set all the other boilers as Followers. It’s that sim-

ple! The XFyre has built-in Lead-Lag control. This allows rotation of the starting boiler so all boilers in the system remain active
and the run times remain equal on each unit. Rotation can even be programmed based on time, ensuring equal run times per
unit.

Содержание XFYRE 500

Страница 1: ...up to 99 Efficiency Can be vented with PVC MBTU Models 300 400 500 700 850 CSA Verified lead Content Less Than 25 Pb Ultra Low Emissions...

Страница 2: ...n ensures efficiency is maintained throughout the firing rate and actually increases during part load right when you want it The XFyre automatically self tunes to accommodate the widest range of gas s...

Страница 3: ...h flexibility XFyre is the right boiler for almost any size job 6 Intake Air Filter Every XFyre comes standard with a front access removable Merv 8 media combustion air filter 7 Manual Reset High Limi...

Страница 4: ...iler Control Raypak uses German made high quality Dungs gas valves considered the finest modulating gas valves produced today To the right of the gas valve is the boiler computer control center which...

Страница 5: ...Input Minimum Input 300 300 282 94 300 285 95 60 400 399 375 94 399 379 95 80 500 500 470 94 500 475 95 100 700 700 658 94 700 665 95 140 850 850 799 94 850 808 95 170 Model Dimensions in A Length Am...

Страница 6: ...GPM DP GPM DP GPM DP DT DP MTS DT GPM SHL GPM MTS DP SHL Do not use when hardness exceeds 15 grains per gallon MTS Minimum Tube Size inch SHL System Head Loss ft based on heater and tank placed no mo...

Страница 7: ...tdoor Sensor Line Voltage Blocked Vent Low Water Level 24 Volt Low Low Water Flow Temper Blocking High Temperature Flue Gas Pressure Supply Thermistor Return Thermistor Supply High Ignition Control Fa...

Страница 8: ...r Reset Sensor N A V Multiple Boiler Controller TempTracker Mod Hybrid up to 16 boilers groups V V Direct Spark Ignition System 1 try V V 4 try v v High Low Gas Pressure Switches V V Blocked Vent Swit...

Отзывы: