background image

4

1. Flue Outlet

Category IV- PVC, CPVC and Stainless steel certified.
The XFyre ships PVC ready, no extras to purchase!

2. High Voltage Wiring Box

120VAC main incoming power connections. Boiler
pump wiring and DHW pump wiring. Alarm power
out.

3. Gas Inlet

The XFyre will operate at 100% full rate with gas pres-
sures as low as 4.0”w.c.

4. Condensate Drain and Trap

3/4”-NPT PVC connection for condensate removal.
Inset photo shows condensate trap, overfill sensor and
pressure switch for the flue. Raypak offers optional
condensate neutralizer kits (option Z-12) that can be
plumbed between the heater and the drain.

5. Direct Vent Capability

Every XFyre is direct vent capable. By installing an
optional combustion air pipe adapter, your XFyre is
ready for direct vent. For factory installation, order
(option D-21) TruSeal

T

at time of order.

6. Rating Plate Location

7. Gas Valve and Boiler Control

Raypak uses German-made, high quality Dungs gas
valves, considered the finest modulating gas valves
produced today. To the right of the gas valve is the
boiler computer control center, which always keeps the
blower, gas valve, direct spark ignition and flame
supervision in perfect harmony.

8. Inlet and Outlet Connections and Flow Switch

The vertical inlet and outlet connections are all copper
and brass fitted with male pipe thread connections.
The flow switch is fully contained within the cabinet,
protecting it from the elements and boiler room
mishaps. Servicing of the Flow switch can be done
from the top or left side.

9. Removable Air Filter

Simple front access; just remove the front door. The fil-
ter just slides right out for quick and easy inspection
and replacement. The high capacity filter is rated
MERV 8.

X

treme Access

7

8

4

9

The 

X

Fyre is purpose built for the 

contractor and service professional.

Loosen wing-nuts

Remove Front Door

Pullout filter media

FRONT ACCESS INTAKE AIR FILTER

1

Completely serviceable from the front, top and both sides!

Содержание XFYRE 500

Страница 1: ...up to 99 Efficiency Can be vented with PVC MBTU Models 300 400 500 700 850 CSA Verified lead Content Less Than 25 Pb Ultra Low Emissions...

Страница 2: ...n ensures efficiency is maintained throughout the firing rate and actually increases during part load right when you want it The XFyre automatically self tunes to accommodate the widest range of gas s...

Страница 3: ...h flexibility XFyre is the right boiler for almost any size job 6 Intake Air Filter Every XFyre comes standard with a front access removable Merv 8 media combustion air filter 7 Manual Reset High Limi...

Страница 4: ...iler Control Raypak uses German made high quality Dungs gas valves considered the finest modulating gas valves produced today To the right of the gas valve is the boiler computer control center which...

Страница 5: ...Input Minimum Input 300 300 282 94 300 285 95 60 400 399 375 94 399 379 95 80 500 500 470 94 500 475 95 100 700 700 658 94 700 665 95 140 850 850 799 94 850 808 95 170 Model Dimensions in A Length Am...

Страница 6: ...GPM DP GPM DP GPM DP DT DP MTS DT GPM SHL GPM MTS DP SHL Do not use when hardness exceeds 15 grains per gallon MTS Minimum Tube Size inch SHL System Head Loss ft based on heater and tank placed no mo...

Страница 7: ...tdoor Sensor Line Voltage Blocked Vent Low Water Level 24 Volt Low Low Water Flow Temper Blocking High Temperature Flue Gas Pressure Supply Thermistor Return Thermistor Supply High Ignition Control Fa...

Страница 8: ...r Reset Sensor N A V Multiple Boiler Controller TempTracker Mod Hybrid up to 16 boilers groups V V Direct Spark Ignition System 1 try V V 4 try v v High Low Gas Pressure Switches V V Blocked Vent Swit...

Отзывы: