How long has the unit been operating? During ini-
tial pool heating in cold weather, it may require a
week to elevate the water temperature to a com-
fortable level. Normally, it takes about 4 days. 

How  many  hours  per  day  is  the  unit  operating?

Remember  that  the  heat  pump  pool  heater  only
operates  while  the  pool  pump  is  running.

Set  the

time clock to permit 24 hour per day operation. After
the desired temperature is reached, return the unit to
normal operation of 8–10 hours per day.

Is  airflow  through  the  unit  being  obstructed?
Restrictions  such  as  shrubbery,  tall  grass,  dirty
coils, or any other obstruction to airflow will reduce
performance.

• 

Is  the  pool  blanket/cover  being  used?
Unblanketed pools can lose up to 10 degrees per
night  compared  to  4  degrees  or  fewer  when  a
blanket is used. Without a blanket, the total heat
gained during the day can be lost overnight.

Are rapid heat losses occurring in some other way,
such as high wind, spillage, rainfall, flow through
solar panels at night, or a high water table?

B. UNIT IS NOT RUNNING

Is  the  temperature  display  ON?  If  not,  the  circuit
breaker  may  be  shut  OFF  or  tripped.  Reset  the
breaker  by  switching  it  OFF,  and  then  back  ON.

Verify  that  the  breaker  is  set  and  operating
properly before calling for service.

Is the thermostat setting and the Pool/Spa setting
correct?  Verify  that  the  temperature  has  been
properly set on the thermostat, and that it is 

high-

er

than the current water temperature.

Have you waited approximately 5 minutes for the
time  delay? After  the  unit  has  been  running  and
then  shut  OFF  for  any  reason,  there  is  a  delay
before operation can begin again.

NOTE:

If the pool pump and heat pump pool heater

shut OFF before the water temperature is raised to
the desired level, you must lengthen the running time
of both. To do this, reset the time clock dial for the
longer running time, or manually operate the pump
with the timer override switch. Since the unit capaci-
ty and efficiency are both greater at higher ambient
air  temperatures,  run  time  should  be  set  to  take
advantage of all daylight hours, when the air is gen-
erally warmer.

Is the 

Heat Light

ON? If not, then the thermostat

setting  is  not  higher  than  the  temperature  of  the
water. Raise the thermostat setting.

C. CONDENSATION SEEMS EXCESSIVE

Heat pump pool heaters can produce a large amount
of  condensation  (water)  during  operation.  If  you  sus-
pect that the unit is leaking:

a.

Use a pool chemistry test kit to confirm there is no
chlorine in the condensation. 

Or,

b.

Shut the unit OFF and leave the filter pump run-
ning to see if the water stops dripping. If the water
stops dripping, the unit is 

not

leaking.

Service Call Verification

NOTE:

The Raypak Service number is 

800-260-2758.

For units in Canada, call 

800-268-6966

.

Before you make a service call, 

first

determine if the

problem is:

Warranty Service

Unit  operation  (power  supply,  water  flow,  or  time
clock adjustment)

Power Supply

Verify that all circuit breakers are reset and work-
ing properly.

If the temperature display still does not light, con-
tact the installing dealer, since it may be a power
problem requiring an electrician.

Water Flow

Verify that the pool filter is clean to provide good
flow.

Verify that valves are properly positioned to allow
adequate water flow through the unit.

NOTE:

The heat pump pool heater will not run when

the 

Remote

position  is  selected  on  the  Pool/Spa

selector  switch  and  there  is  no  remote  control  sys-
tem attached.

NOTE:

The 

MANUFACTURER  IS  NOT  RESPON-

SIBLE

for these adjustments.

Содержание Professional PS10353ti-E-HC

Страница 1: ...C PS10355ti E HC Heat Pump Pool Spa Heater US C LISTED R NOTE The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and maintenance of this type of equipment and related system components Installation and service personnel are required by some states to be licensed Persons not qualified shall not attempt to install service or...

Страница 2: ...2 ...

Страница 3: ...M 4500 MAXIMUM 4500 MAXIMUM 4500 MAXIMUM Free Chlorine PPM 2 to 3 2 to 3 2 to 3 Total Dissolved Solids PPM 3000 MAXIMUM 3000 MAXIMUM 3000 MAXIMUM Free Chlorine MUST NOT EXCEED 5 PPM In salt water chlorinated pools the total TDS can be as high as 6000ppm Occasional chemical shock dosing of the pool or spa water should not damage the heater providing the water is balanced Automatic chemical dosing d...

Страница 4: ...eat Cool Operation 11 System Start Up 11 Seasonal Start Up or Annual Check 11 Summer Shutdown 11 Freeze Protection 12 System Drain Down 12 Continuous Pump Operation 12 Maintenance 12 Air Coil Cleaning 12 Cabinet Care optional 12 Unplug Condensation Drain Holes 12 Troubleshooting 12 Service Call Verification 13 Power Supply 13 Water Flow 13 Time Clock Adjustment 14 Plumbing Diagrams 15 Wiring Diagr...

Страница 5: ...nd the heat pump pool heater CAUTION Elevated water temperature can be hazardous The U S Consumer Product Safety Commission has these guidelines 1 Spa water temperatures should never exceed 104 F 40 C A temperature of 100 F 38 C is considered safe for a healthy adult Special cau tion is suggested for young children 2 Drinking of alcoholic beverages before or during spa or hot tub use can cause dro...

Страница 6: ...tion each side of the unit at least 1 ft 30 cm from walls pipes and other obstructions Recirculation of cold discharge air back into the evaporator coil will greatly reduce the unit s heat ing capacity and efficiency This unit features an up flow discharge for quiet operation Air is pulled up through the evaporator coil and discharged through the top grill Allow at least 5 ft 1 5 m clearance above...

Страница 7: ...ational Electrical Code NFPA No 70 latest edition and all applicable state and local codes Wiring diagrams are located on pages 19 through 21 Locate the equipment disconnect means within 3 feet of the heater s electrical enclosure or as close to the heater as possible Always satisfy applicable codes and standards In sizing power wiring be especially aware of up sizing requirements necessary due to...

Страница 8: ...8 SEE BRACKET HURRICANE TIE DOWN DWG 50 1 2 10353 10354 10355 50 1 2 50 1 2 ...

Страница 9: ...ual in size to the main pool spa circulation pip ing 4 In cold weather freeze zone areas shutoff valves ball or gate type must be installed at the unit inlet and outlet to facilitate service and cold weather drain down 5 Operate the pump and check the system for leaks Pressure Drop For system pressure drop information refer to Table B below CAUTION The heat pump pool heater inlet and outlet connec...

Страница 10: ...T key until you see P _S and by pressing the UP or DOWN key you can switch to POL or SPA To Increase the Desired Water Temperature Pool or Spa Mode Push the SET key until you see POL or SPA The pro grammed temperature will be displayed Press the UP arrow to increase the temperature setting one degree at a time To Lower the Desired Water Temperature Pool or Spa Mode Push the SET key until you see P...

Страница 11: ...fountains sprays or other water features to speed cooling NOTE Heating is more efficient during warmer day light hours and cooling is more efficient during cooler night time hours Seasonal Start Up or Annual Check 1 Remove leaves pine needles etc from the evap orator coil Clean the coil by gently applying a mild solution of household liquid soap and water 2 Gently rinse the coil with water DO NOT ...

Страница 12: ...er pipes This is also evidence of heat removal from the air When the air is cool with low humidity condensation may not be evident WARNING Shut OFF electricity to the unit before cleaning Freeze Protection If the unit is installed in a location subject to freezing conditions it is important to protect the water circuit from freezing just as should be done for the pump and filter System Drain Down ...

Страница 13: ...and heat pump pool heater shut OFF before the water temperature is raised to the desired level you must lengthen the running time of both To do this reset the time clock dial for the longer running time or manually operate the pump with the timer override switch Since the unit capaci ty and efficiency are both greater at higher ambient air temperatures run time should be set to take advantage of a...

Страница 14: ...ne temperature sensor is open or may be defective FLO Possible causes The filter is in backwash position The filter pump is stopped The filter is dirty Shortage of water to pool pump FIL parameter must be set to activate pool pump Water flow switch may be broken FL3 The unit has encountered 3 FLO faults within the same call for heat and shut down the unit for protection If this occurs you should c...

Страница 15: ...CHECK VALVE CHEMICAL INTRODUCTION WATER OUT TO POOL OR SPA Fig 6 For systems with pumps of less than 2 HP under 80 gpm no external bypass is required Connections are 2 inch unions Plumb the heat pump pool heater AFTER the filter and BEFORE any chlorinators ...

Страница 16: ...PA Fig 7 For systems with pumps of 2 HP or greater over 80 gpm an external bypass is required Adjust the bypass valve to divert a minimum of 40 gpm through the heat pump pool heater Connections are 2 inch unions Plumb the heat pump pool heater AFTER the filter and BEFORE any chlorinators 16 ...

Страница 17: ...Fig 8 Pool Piping for Heat Pump Pool Heater and Gas Pool Heater 17 ...

Страница 18: ...ry Secondary BRANCH MAIN BRANCH MAIN BRANCH MAIN 15 GPM 2 2 15 GPM 2 2 15 GPM 2 2 30 2 2 30 2 2 1 2 30 2 3 45 2 2 45 2 3 45 2 4 60 2 2 1 2 60 2 3 60 2 4 80 2 3 80 2 4 80 2 5 Sizing based on 10 ft sec flow rates MINIMUM PIPE SIZES 2 UNITS 3 4 UNITS 5 6 UNITS 18 ...

Страница 19: ...19 Wiring Diagram 208V 230V 3Ph 60Hz Models ...

Страница 20: ...Wiring Diagram 460V 3Ph 60 Hz Models 20 ...

Страница 21: ...21 Wiring Diagram 380V 3Ph 60 Hz Models ...

Страница 22: ... until OFF is displayed Wait until a temperature is displayed before beginning the next step 2 Push the SET key until SPA is displayed then push the UP arrow to 104 F Wait until a tempera ture is displayed before beginning the next step 3 Push the SET key until P_S is displayed then push the DOWN arrow until POL is displayed Wait until a temperature is displayed before begin ning the next step 4 F...

Страница 23: ...23 ...

Страница 24: ...24 Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Heat Pump Service 1 800 260 2758 Litho in U S A ...

Отзывы: