Controls 

Your heat pump pool heater incorporates digital safety
controls  and  indicators  to  ensure  its  safe,  reliable
operation.

Water Pressure Switch:

Prevents operation when the

pump is OFF. The unit requires 5 psi minimum pres-
sure.

Digital Water Temperature Control:

The pool water

temperature  is  controlled  by  the  heat  pump  pool
heater’s  digital  control  system,  which  gives  you  the
option of two settings: one for the desired spa temper-
ature and the other for the desired pool temperature.
Additionally, as mentioned earlier, the unit is compati-
ble  with  most  ‘2-wire’  and  ‘3-wire’  control/automation
systems.

Defrost Sensor:

Prevents unit operation if ambient air

temperature  falls  below  a  predetermined  safe  mini-
mum (approximately 42°–48°F (5.5

°

-8.8

°

C) based on

humidity). The  compressor  will  shut  OFF  but  the  fan
will continue to run.

Delay Timer:

Prevents compressor from short cycling,

which  could  damage  or  destroy  the  hermetic
motor/compressor.  Upon  water  temperature  control
satisfaction,  or  other  circuit  interruptions,  this  solid
state  device  will  prevent  compressor  restart  for
approximately 5 minutes.

Operating Instructions

The electronic board has the capability of memorizing
two different programmed temperature settings as fol-
lows (refer to Fig. 5):

• 

For a pool, maximum 95°F (35°C)

• 

For a spa, maximum 104°F (40°C)

To Select Pool or Spa Mode

To have access to either one of these programs, press
the 

SET

key until you see 

P _S

and by pressing the

UP or DOWN key you can switch to 

POL

or 

SPA

.

To Increase the Desired Water

Temperature (Pool or Spa Mode)

Push the 

SET

key until you see 

POL

or 

SPA

. The pro-

grammed temperature will be displayed. Press the UP
arrow to increase the temperature setting one degree
at a time.

To Lower the Desired Water

Temperature (Pool or Spa Mode)

Push the 

SET

key until you see 

POL

or 

SPA

. The pro-

grammed  temperature  will  be  displayed.  Press  the
DOWN arrow to decrease the temperature setting one
degree at a time.

Once the control has been programmed to the desired
pool water temperature, the programmed temperature
will  be  displayed  for  approximately  5  seconds.  Then
the  digital  display  will  display  the  actual  pool  water
temperature.

To  make  the  Board  a  Pool  ONLY  Board,  call  800-
260-2758 for instructions.

To Select Temperature in °C or °F

Press the 

SET

key until you see 

F _C

. By pressing the

UP or DOWN key you can switch to 

°F

or 

°C

. Once the

temperature  display  mode  has  been  programmed  it
will  be  displayed  for  approximately  5  seconds,  then
the  digital  display  will  return  to  the  actual  pool  water
temperature in the mode that you have chosen.

Fig. 5: Digital Water Temperature Control

WARNING:

Install a check valve and/or a Hartford

loop  AFTER  the  heat  pump  pool  heater  and
BEFORE any chlorinating devices. Install any auto-
matic chemical feeders AFTER the heat pump pool
heater.

Improper installation of any type of auto-

matic  chemical  feeders  can  result  in  serious
damage  to,  or  premature  failure  of,  the  heat
pump  pool  heater  and  will  void  the  heat  pump
pool heater warranty.

Содержание Professional PS10353ti-E-HC

Страница 1: ...C PS10355ti E HC Heat Pump Pool Spa Heater US C LISTED R NOTE The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and maintenance of this type of equipment and related system components Installation and service personnel are required by some states to be licensed Persons not qualified shall not attempt to install service or...

Страница 2: ...2 ...

Страница 3: ...M 4500 MAXIMUM 4500 MAXIMUM 4500 MAXIMUM Free Chlorine PPM 2 to 3 2 to 3 2 to 3 Total Dissolved Solids PPM 3000 MAXIMUM 3000 MAXIMUM 3000 MAXIMUM Free Chlorine MUST NOT EXCEED 5 PPM In salt water chlorinated pools the total TDS can be as high as 6000ppm Occasional chemical shock dosing of the pool or spa water should not damage the heater providing the water is balanced Automatic chemical dosing d...

Страница 4: ...eat Cool Operation 11 System Start Up 11 Seasonal Start Up or Annual Check 11 Summer Shutdown 11 Freeze Protection 12 System Drain Down 12 Continuous Pump Operation 12 Maintenance 12 Air Coil Cleaning 12 Cabinet Care optional 12 Unplug Condensation Drain Holes 12 Troubleshooting 12 Service Call Verification 13 Power Supply 13 Water Flow 13 Time Clock Adjustment 14 Plumbing Diagrams 15 Wiring Diagr...

Страница 5: ...nd the heat pump pool heater CAUTION Elevated water temperature can be hazardous The U S Consumer Product Safety Commission has these guidelines 1 Spa water temperatures should never exceed 104 F 40 C A temperature of 100 F 38 C is considered safe for a healthy adult Special cau tion is suggested for young children 2 Drinking of alcoholic beverages before or during spa or hot tub use can cause dro...

Страница 6: ...tion each side of the unit at least 1 ft 30 cm from walls pipes and other obstructions Recirculation of cold discharge air back into the evaporator coil will greatly reduce the unit s heat ing capacity and efficiency This unit features an up flow discharge for quiet operation Air is pulled up through the evaporator coil and discharged through the top grill Allow at least 5 ft 1 5 m clearance above...

Страница 7: ...ational Electrical Code NFPA No 70 latest edition and all applicable state and local codes Wiring diagrams are located on pages 19 through 21 Locate the equipment disconnect means within 3 feet of the heater s electrical enclosure or as close to the heater as possible Always satisfy applicable codes and standards In sizing power wiring be especially aware of up sizing requirements necessary due to...

Страница 8: ...8 SEE BRACKET HURRICANE TIE DOWN DWG 50 1 2 10353 10354 10355 50 1 2 50 1 2 ...

Страница 9: ...ual in size to the main pool spa circulation pip ing 4 In cold weather freeze zone areas shutoff valves ball or gate type must be installed at the unit inlet and outlet to facilitate service and cold weather drain down 5 Operate the pump and check the system for leaks Pressure Drop For system pressure drop information refer to Table B below CAUTION The heat pump pool heater inlet and outlet connec...

Страница 10: ...T key until you see P _S and by pressing the UP or DOWN key you can switch to POL or SPA To Increase the Desired Water Temperature Pool or Spa Mode Push the SET key until you see POL or SPA The pro grammed temperature will be displayed Press the UP arrow to increase the temperature setting one degree at a time To Lower the Desired Water Temperature Pool or Spa Mode Push the SET key until you see P...

Страница 11: ...fountains sprays or other water features to speed cooling NOTE Heating is more efficient during warmer day light hours and cooling is more efficient during cooler night time hours Seasonal Start Up or Annual Check 1 Remove leaves pine needles etc from the evap orator coil Clean the coil by gently applying a mild solution of household liquid soap and water 2 Gently rinse the coil with water DO NOT ...

Страница 12: ...er pipes This is also evidence of heat removal from the air When the air is cool with low humidity condensation may not be evident WARNING Shut OFF electricity to the unit before cleaning Freeze Protection If the unit is installed in a location subject to freezing conditions it is important to protect the water circuit from freezing just as should be done for the pump and filter System Drain Down ...

Страница 13: ...and heat pump pool heater shut OFF before the water temperature is raised to the desired level you must lengthen the running time of both To do this reset the time clock dial for the longer running time or manually operate the pump with the timer override switch Since the unit capaci ty and efficiency are both greater at higher ambient air temperatures run time should be set to take advantage of a...

Страница 14: ...ne temperature sensor is open or may be defective FLO Possible causes The filter is in backwash position The filter pump is stopped The filter is dirty Shortage of water to pool pump FIL parameter must be set to activate pool pump Water flow switch may be broken FL3 The unit has encountered 3 FLO faults within the same call for heat and shut down the unit for protection If this occurs you should c...

Страница 15: ...CHECK VALVE CHEMICAL INTRODUCTION WATER OUT TO POOL OR SPA Fig 6 For systems with pumps of less than 2 HP under 80 gpm no external bypass is required Connections are 2 inch unions Plumb the heat pump pool heater AFTER the filter and BEFORE any chlorinators ...

Страница 16: ...PA Fig 7 For systems with pumps of 2 HP or greater over 80 gpm an external bypass is required Adjust the bypass valve to divert a minimum of 40 gpm through the heat pump pool heater Connections are 2 inch unions Plumb the heat pump pool heater AFTER the filter and BEFORE any chlorinators 16 ...

Страница 17: ...Fig 8 Pool Piping for Heat Pump Pool Heater and Gas Pool Heater 17 ...

Страница 18: ...ry Secondary BRANCH MAIN BRANCH MAIN BRANCH MAIN 15 GPM 2 2 15 GPM 2 2 15 GPM 2 2 30 2 2 30 2 2 1 2 30 2 3 45 2 2 45 2 3 45 2 4 60 2 2 1 2 60 2 3 60 2 4 80 2 3 80 2 4 80 2 5 Sizing based on 10 ft sec flow rates MINIMUM PIPE SIZES 2 UNITS 3 4 UNITS 5 6 UNITS 18 ...

Страница 19: ...19 Wiring Diagram 208V 230V 3Ph 60Hz Models ...

Страница 20: ...Wiring Diagram 460V 3Ph 60 Hz Models 20 ...

Страница 21: ...21 Wiring Diagram 380V 3Ph 60 Hz Models ...

Страница 22: ... until OFF is displayed Wait until a temperature is displayed before beginning the next step 2 Push the SET key until SPA is displayed then push the UP arrow to 104 F Wait until a tempera ture is displayed before beginning the next step 3 Push the SET key until P_S is displayed then push the DOWN arrow until POL is displayed Wait until a temperature is displayed before begin ning the next step 4 F...

Страница 23: ...23 ...

Страница 24: ...24 Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Heat Pump Service 1 800 260 2758 Litho in U S A ...

Отзывы: