Raypak MVB 503 Скачать руководство пользователя страница 8

MVB

HEA

EXCHANGER

JACKET

OTHER

GAS 

TRAIN

SAFETIES

OPERA

TING 

CONTROLS

ASME, National Board Registered, 160 PSI

• HLW Stamp

N/A

• H Stamp

N/A

Heat Exchanger Tubes

• Copper

• Cupro Nickel

Bronze Headers

Cast Iron Headers

N/A

Pressure Relief Valve

• 60 PSI

• 125 PSI

• 30, 45, 75, 150 PSI

Temperature & Pressure Gauge

Pump

• 120V, Single-Phase

Indoor/Outdoor Certified

Vent Terminal

• Outdoor
• Through-The-Wall

Fully-Enclosed Controls

Combustible Floor Rated

120V Power Supply With 120V/24V Transformer

On/Off Switch

Programmable Pump Time Delay, Single-Phase

• Included In TempTracker Mod Controller

Terminal Block Connections

• Enable / Disable

• External Interlocks

• 0-10 VDC Setpoint/Direct Drive Input

Diagnostic LCD Display With Up To 16 Faults

Status Display Lights (4)

Temperature Controller With 3 Water Sensors

• TempTracker Mod (Up To 4:1 Turndown, Cat. IV)

• Outdoor Reset Sensor

N/A

Multiple Boiler Controller

• TempTracker Mod+ Hybrid BACnet, Up To 16 boilers
• Multi-Mod Platinum (BACnet)

Hot Surface Ignition System

• 1-Try (Standard On Cat. IV)
• 3-Try (Standard On Cat. I)

High/Low Gas Pressure Switches
Blocked Vent And Air Pressure Switches

High Limit Switch

• Manual Reset, Fixed

• Manual Reset, Adjustable
• Automatic Reset, Adjustable

Low Water Cut-Off, 24V

• With Manual Reset And Test Buttons

Flow Switch

Modulating Combination Gas Valve

Combustion Air Blower

TruSeal Direct-Vent Ready

Additional Safety Valve

• Motorized (Externally Mounted)
• Solenoid (Externally Mounted)

CSA-Certified Efficiency

• Cat. IV - 87% At Full Fire

• Cat. I - 84% to 85% (See MBTUH Table)

Air Filter (Shipped Loose)

Alarm System
CSD-1 / GE GAP Control System
Low NOx

• Meets All Current Requirements

Cold Water Start

• Prevents Internal Condensation On Start-Up

Cold Water Run

• Prevents Condensation In Continuous Low-Temp Operation

Water Heaters

(Type WH)

Boilers

(Type H)

 

 

= Standard       

 

 

= Optional

Raypak, Inc.

•  2151 Eastman Avenue, Oxnard, CA 93030 • phone: (805) 278-5300 • fax: (800) 872-8725 • www.raypak.com

Cat. No. 3400.11H   Effective 05-01-11    Replaces 02-15-10

LLC

®

Содержание MVB 503

Страница 1: ...Models 504 thru 2004 Category I with vertical vent Models 503 thru 2003 Category IV Venting Up to 88 4 thermal efficiency CSA Certified Lead Content Less Than 25 Pb...

Страница 2: ...ensate which may form during initial start up or brief periods of cold water operation eliminating the need for a boiler condensate drain This saves you money on installation costs as well as the head...

Страница 3: ...front and easy to get to Makes sensor wiring and external control wiring simple and clean 13 Drain Valves Two drain valves located at the bottom of the heat exchanger This allows for complete winteriz...

Страница 4: ...260 84 1425 1211 85 1071 2004 I 1999 1679 84 1900 1615 85 1428 MBTUH Models Dimensions inches Operating Weight lbs Amps MVB Cat I MVB Cat IV B Ht D E F G NPT H NPT K Cat I K Cat IV M Cat I M Cat IV N...

Страница 5: ...Unobstructed Front Open 24 Vent Stack Indoor 1 1 Vent Cap Outdoor 12 12 CLEARANCES MVB Model Water Hardness Soft Medium Hard HP Amps HP Amps HP Amps 503 504 1 4 6 1 4 6 3 4 11 753 754 1 4 6 1 2 7 3 4...

Страница 6: ...mum Flow 20 F 30 F GPM P FT T F GPM P FT T F GPM P FT GPM P FT 504 50 2 8 17 100 11 3 8 N A N A 28 1 4 754 50 3 5 25 100 13 8 13 64 6 1 42 3 0 1104 60 6 3 30 113 18 6 16 90 12 6 60 6 3 1504 82 12 6 30...

Страница 7: ...018 933 862 800 747 1500 15 273 7 636 5 091 3 818 3 055 2 545 2 182 1 909 1 697 1 527 1 388 1 273 1 175 1 091 1018 1999 20 353 10 177 6 784 5 088 4 071 3 392 2 908 2 544 2 261 2 035 1 850 1 850 1 566...

Страница 8: ...ller TempTracker Mod Hybrid BACnet Up To 16 boilers Multi Mod Platinum BACnet Hot Surface Ignition System 1 Try Standard On Cat IV 3 Try Standard On Cat I High Low Gas Pressure Switches Blocked Vent A...

Отзывы: