Raypak MVB 503 Скачать руководство пользователя страница 3

1. Control Panel

Fully enclosed controls and wiring protect against dam-
age or vandalism. Cabinet design affords easy access to
controls for installation and service.

2. Temp-Tracker Mod Control

This factory-mounted multi-function control
delivers precise load-tracking with selectable
mode displays that are easy to access and read.

3. On Board Diagnostic Center

Factory-mounted standard equipment. Gives relevant
service feedback as well as possible solutions to clear
the fault. All in plain English, no cryptic codes to deci-
pher. The control also stores up to 16 fault codes in its
history file for the service technician to review.

4. Weather-Proof Jacket

Heavy gauge galvanized steel with a UV-resistant
Polytuf powder coat finish is impervious to weather and
corrosion.

5. Combustion Air Fan

Cast aluminum, non-sparking construction.

6. Vent Pressure Switch

Monitors vent pressure and provides safe shut down if
back pressure is excessive.

7. Minimum Clearance Requirements

Only one inch of side clearance is required from 
combustible surfaces.

8. Vertical Heat Exchanger

Cylindrical, multi-pass heat exchanger captures all radi-
ant energy, eliminating the need for heavy refractory.

9. Rugged Cast Headers

Bronze headers standard on water heater models. Cast-
iron standard on boiler models, with bronze headers
optional.

10. Tube Sheet Construction

Eliminates the repair & maintenance problems associat-
ed with rolled-tube construction. Easy, cost-effective
component replacement.

11. Viewing Port

Allows easy burner inspection.

12. Low Voltage Wiring Connections

Up front and easy to get to. Makes sensor wiring and
external control wiring simple and clean.

13. Drain Valves

Two drain valves located at the bottom of the heat
exchanger. This allows for complete winterizing and
drainage of the heater.

1

2

3

10

4

6

9

7

8

11

13

12

Cold Water Solutions

Cold Water Start

– For applications that

require reliable protection against harmful con-
densation caused by frequent, extended, cold
water start-ups. Raypak’s Cold Water Start pro-
tection system utilizes a proportional three-
way valve to bypass water from the boiler out-
let to the inlet during start-up, when the sys-

tem return water temperature is below the minimum acceptable
level. (See Cat. #1000.19)

Cold Water Run

– For applications requir-

ing constant condensation protection. Raypak’s
Cold Water Run system utilizes a variable-
speed pump to inject just the right amount of
water from the main system loop into the boil-
er to maintain the optimum inlet temperature.
This approach allows the full capacity of the
boiler to be utilized to meet the system load,

while at the same time continuously maintaining the optimum inlet
water temperature to prevent condensation. (See Cat. #1000.19)

Multi Boiler Solutions

State of the art European combustion technology

Optional Equipment

3

TempTracker Mod+ Hybrid

– Controls up

to 16 Raypak boilers with PID logic. Automatic
or manually selectable lead-lag boiler opera-
tion. TempTracker Mod+ Hybrid monitors and
displays supply water temperatures on all
applications including outdoor temperature
when outdoor reset mode is selected. Can
also be used to control a mix of condensing
and non condensing boilers using our Hybrid
control algorithm. Now available with 
optional BACnet

®

BMS link.

(See Cat. # 5100.22) 

Hybrid Control

BACnet BMS Link

Содержание MVB 503

Страница 1: ...Models 504 thru 2004 Category I with vertical vent Models 503 thru 2003 Category IV Venting Up to 88 4 thermal efficiency CSA Certified Lead Content Less Than 25 Pb...

Страница 2: ...ensate which may form during initial start up or brief periods of cold water operation eliminating the need for a boiler condensate drain This saves you money on installation costs as well as the head...

Страница 3: ...front and easy to get to Makes sensor wiring and external control wiring simple and clean 13 Drain Valves Two drain valves located at the bottom of the heat exchanger This allows for complete winteriz...

Страница 4: ...260 84 1425 1211 85 1071 2004 I 1999 1679 84 1900 1615 85 1428 MBTUH Models Dimensions inches Operating Weight lbs Amps MVB Cat I MVB Cat IV B Ht D E F G NPT H NPT K Cat I K Cat IV M Cat I M Cat IV N...

Страница 5: ...Unobstructed Front Open 24 Vent Stack Indoor 1 1 Vent Cap Outdoor 12 12 CLEARANCES MVB Model Water Hardness Soft Medium Hard HP Amps HP Amps HP Amps 503 504 1 4 6 1 4 6 3 4 11 753 754 1 4 6 1 2 7 3 4...

Страница 6: ...mum Flow 20 F 30 F GPM P FT T F GPM P FT T F GPM P FT GPM P FT 504 50 2 8 17 100 11 3 8 N A N A 28 1 4 754 50 3 5 25 100 13 8 13 64 6 1 42 3 0 1104 60 6 3 30 113 18 6 16 90 12 6 60 6 3 1504 82 12 6 30...

Страница 7: ...018 933 862 800 747 1500 15 273 7 636 5 091 3 818 3 055 2 545 2 182 1 909 1 697 1 527 1 388 1 273 1 175 1 091 1018 1999 20 353 10 177 6 784 5 088 4 071 3 392 2 908 2 544 2 261 2 035 1 850 1 850 1 566...

Страница 8: ...ller TempTracker Mod Hybrid BACnet Up To 16 boilers Multi Mod Platinum BACnet Hot Surface Ignition System 1 Try Standard On Cat IV 3 Try Standard On Cat I High Low Gas Pressure Switches Blocked Vent A...

Отзывы: