background image

Catalog No.:  2100.20M 

Effective:  6-15-07 

Replaces:  6-15-02

 

Raypak Residentials 
Hydronic Heating Boilers 

Model 

           

 

 

 

 
 

 

 

 

Piping Connections

Clearances 

Model

1

 

 

Input 

MBTUH

2

 

Heating 

Capacity 

MBTUH 

Net I=B=R 

Rating 

MBTUH 

Water 

NPT 

Gas NPT

 
 

Vent 

Diameter

Approx. 

Shipping 

Weight (lbs)

Front 

Other 
Sides 

Top 

Flue 

Vent 

0042 

42 

35 30 

1" 

1/2" 

5-1/2" 

4" 95 4" 

6" 

16" 

6" 

0066 

66 

54 47 1" 

1/2" 

5-3/4" 

5" 105 4" 

6" 

16" 

6" 

0090 90 

74 

64 

1"  1/2" 

5-3/4" 5" 

105  Alcove 

6" 16" 6" 

0135 135  109 

95  1-1/4" 1/2" 6-1/4"  6" 

135  Alcove 6" 16" 6" 

0180 

180 148 129 

1-1/4" 

1/2" 8" 7"  140 Alcove 

6" 

16" 

6" 

 

Notes: 
1.  Standard models, use “H-” prefix (e.g., H-0042); Non-ferrous models, use “HB-” prefix (e.g., HB-0042) 
2.  Per Section 11.1.2 of the National Fuel Gas Code, derate the appliance firing rate 4% per 1,000 feet above sea level for installations above 

2,000 feet. 

 
 
 

 

Models 42, 66 & 90 

 

Models 135 & 180 

Raypak, Inc. 

ƒ

 2151 Eastman Avenue, Oxnard, CA  93030 

ƒ

 (805) 278-5300 

ƒ

 Fax (800) 872-9725 

ƒ

 www.raypak.com 