background image

Catalog No.:  2100.20M 

Effective:  6-15-07 

Replaces:  6-15-02 

Job: 

 

           

 

Engineer: 

 

           

 

Contractor: 

 

           

 

Prepared By: 

            

 Date: 

            

 

Model: 

             

 Indoor/Outdoor:  

           

 

 

 

Applications 

ƒ

 Radiant 

Heating 

ƒ

  Hydronic Space Heating 

ƒ

 Snow 

Melting 

High Efficiency 

Heating efficiencies meet or 
exceed NAECA standards. 

Factory Installed Circulator 
and Bypass 

Thermostatically-controlled 
circulator maintains proper flow 
through the boiler. As a packaged 
system, installation is fast and 
easy. 

Electronic Ignition 

Intermittent pilot ignition improves 
system efficiency by using fuel 
only when there is a call for heat. 

Compact, Lightweight Design 

Even the largest model slips 
easily into tight spaces. 

Easy to Plumb, Easy to Service 

Inlet and outlet water piping, gas 
connection, wiring and controls 
are all up front for easy access. 

Safe Operation 

Built-in manual reset safety 
sensors shut down the boiler in 
the event of a flame roll-out or 
flue gas spillage. Normal working 
pressure is 125 PSI max. 

Fast Response Temperature 
Sensor 

Electronic solid state auto-reset 
control shuts down the boiler in 
the event of over-heating caused 
by a low-flow condition. 
 
 

Heat Exchanger 

ƒ

  ASME Inspected and Stamped 

160 PSIG 

ƒ

  National Board Approved 

ƒ

  Glass-lined Cast Iron Headers 

ƒ

 Copper 

Finned 

Tubing 

ƒ

  ASME Steel Tube Sheet 

ƒ

 Silicone 

O-Rings 

ƒ

  30 PSIG ASME Pressure Relief Valve 

ƒ

  Temperature and Pressure Gauge 

ƒ

  Cast Iron Pump – 120 VAC, Mounted 

ƒ

 Bypass 

Assembly 

 Non-Ferrous Options 

ƒ

  All Bronze Pump, 120 VAC, Mounted 

ƒ

 Bronze 

Fittings 

 
 

Controls 

ƒ

  120V, 60Hz, 1 Ph Power Supply 

ƒ

 120/24V 

Transformer 

ƒ

 Pilot 

 Electronic, Intermittent Ignition 

(IID) - Standard 

 Standing (Thermocouple) - 

Models 90, 135 and 180 only 

ƒ

  100% Pilot Shut-off/Lockout (IID only) 

ƒ

 High 

Limit 

Control 

ƒ

  Operating Limit Control 

ƒ

 Flow 

Sensor 

ƒ

  Flue Gas Spillage Sensor 

ƒ

  Flame Rollout Sensor 

ƒ

  Automatic Vent Damper 

Gas Control Train 

ƒ

 Fuel 

 Natural Gas 
 Propane Gas     

ƒ

 Firing 

Mode 

- On/Off - Models 42-66 
- Two-stage Firing - Models 90-180 

ƒ

  Combination Gas Valve 

- Manual Shut-off 
- Redundant Valve Features 
- Gas Pressure Regulator 

Construction 

ƒ

 Indoor 

Construction 

ƒ

  Enclosed Front Controls 

ƒ

  Stainless Steel Burners 

ƒ

  Polytuf Powder Coat Finish 

ƒ

  Built-in Draft Diverter 

ƒ

  Certified for combustible flooring 

 

 

 

 

Raytherm™ Residentials

Hydronic Heating Boilers

Models 42-180

AFUE Ratings* 

Model AFUE 

0042 84 
0066 83 
0090 83 
0135 83 
0180 83 

*Tested with IID ignition and vent damper

 

Fig. #8942

Отзывы: