Kit Contents
Each kit includes:
(1) Temperature and Pressure gauge
(1) Pre-wired Flow Switch with outdoor cover
(2) Paddles
(1) Screw, #6-32 x 3/16
(1) 2” CPVC Tailpiece Connector
(1) 2” CPVC Manifold Adapter
(1) O-Ring
(2) Female spade terminals
(1) Ring nut
This kit is primarily intended for jurisdictions requiring
the addition of a flow switch and/or temperature and
pressure gauge on pool heaters.
Before Starting
1) Turn off power to the heater at the circuit breaker.
2) Turn off gas supply.
3) Shut off the water supply to the heater.
4) Allow heater to cool down before attempting work.
INSTALLATION
1. Remove main front panel door and set aside.
2. Remove the front control panel screws (2 each
located at the ends of the panel). Lower front
panel to expose the main circuit board.
3. Remove transformer cover located on either the
upper right or left side.
4. Locate conduit opening above power conduit
opening on the waterside of the heater.
5. Locate the Inlet/Outlet header.
6. Install 2” flanges to header ports, if not already
installed.
NOTE:
These instructions are intended primarily for
use by qualified personnel specifically trained and
experienced in the installation of this type of heating
equipment and related system components.
Installation and service personnel must be licensed
in some states. Persons not qualified shall not
attempt to install this equipment nor attempt repairs
according to these instructions.
DANGER - SHOCK HAZARD:
Make sure electri-
cal power to the heater is disconnected to avoid
potential serious injury or damage to components.
PLUMBING
CPVC TAILPIECE
O-RING & RING NUT
(SUPPLIED)
CPVC MANIFOLD
(SUPPLIED)
T&P GAUGE
(SUPPLIED)
GASKETS, FLANGES
& BOLTS
(WITH ORIGINAL EQUIPMENT)
FLOW SWITCH COVER
(SUPPLIED)
MALE CPVC CONNECTOR
(WITH ORIGINAL EQUIPMENT)
Fig. 1: Flow Switch and Temperature and Pressure Gauge