background image

INSTALLATION 

15 

 

HOT WATER DELIVERY (WATER HEATING APPLICATIONS) 

This water heater can deliver water at temperatures which can cause scalding. 

It is necessary and we recommend that a temperature limiting device be fitted between the water heating system 
and  the  hot  water  outlets  in  any  ablution  and  public  areas  such  as  bathrooms,  ensuites  or  public  amenities,  to 
reduce  the  risk  of  scalding.  The  installing  plumber  may  have  a  legal  obligation  to  ensure  the  installation  of  this 
water  heater  meets  the  delivery  water  temperature  requirements  of  AS/NZS 3500.4  so  that  scalding  water 
temperatures are not delivered to a bathroom, ensuite, or other ablution or public area. 

Where a temperature limiting device is installed adjacent to the hot water storage tanks, the cold water line to the 
temperature  limiting  device  can  be  branched  off  the  cold  water  line  either  before  or  after  the  isolation  valve, 
pressure limiting valve and non return valve to the storage tanks. If an expansion control valve is required, it must 
always be installed after the non return valve and be the last valve prior to the water heating system. 

If a pressure limiting valve is installed on the cold water line to the water heating system and the cold water line to a 
temperature limiting device branches  off before this valve or from another cold  water  line in the premises, then a 
pressure limiting valve of an equal pressure setting may be required prior to the temperature limiting device. 

REDUCING HEAT LOSSES (WATER HEATING APPLICATIONS) 

The  cold  water  line  to  and  the  hot  water  line  from  the  storage  cylinder  must  be  insulated  in  accordance  with  the 
requirements of AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if exposed. 

Keep temperature settings down. Lower temperatures reduce heat losses and prolong storage cylinder life. Do not 
set  the  controlling  electronic  thermostat  above  70°C  unless  it  is  necessary.  A  time  clock  to  control  the  electrical 
supply can be used to switch off the water heater during hours or days when it is not in use. 

HOOD CONVERSION 

To convert a water heater from an outdoor configuration to an Indoor or High Wind Top configuration, proceed as 
follows: 

1.  Remove the flue terminal (outdoor hood) from the water heater leaving the jacket top in place. 

Place the stack adaptor over the flue collector and secure into place with self tapping screws. 

Fit the  draft diverter  over the spigot and sit squarely  on the stack adapter.  Secure in place  using self tapping 

screws. 

(Indoor  installations  only)  Install  and  connect  the  secondary  flue  to  the  draft  diverter  in  accordance  with  the 

requirements of AS 5601. 

NOTE

: For High Wind Top conversion follow steps 1  to 3  and assess whether tie downs for the High Wind Cowl 

are required. 

Содержание B0200

Страница 1: ...stallation Instructions Raypak Water Heaters Models Types B0200 NCO NCM PCO PCM B0280 B0350 B0430 This water heater must be installed and serviced by a qualified person Please leave this guide with a...

Страница 2: ...to install this water heater and ask for your Compliance Certificate Warning Upon completion of the installation and commissioning of the water heater leave this guide with the householder or a respo...

Страница 3: ...terest CONTENTS 3 ABOUT YOUR WATER HEATER 4 HOW YOUR WATER HEATER WORKS 7 SAVE A SERVICE CALL 8 REGULAR CARE 10 INSTALLATION 11 CONNECTIONS PLUMBING 17 CONNECTIONS ELECTRICAL 20 LOCATION OF CONTROLS 2...

Страница 4: ...uitable for the application and will not cause scald injury We recommend and it may be required by regulations that an approved temperature limiting device be fitted into the hot water piping to the b...

Страница 5: ...Propane model A Propane model is designed to operate on Propane only The use of Propane Butane mixture such as automotive LPG fuel in a Propane model is unsafe and can cause damage to the water heater...

Страница 6: ...ribed on pages 35 HOW LONG WILL THE WATER HEATER LAST The water heater is supported by a manufacturer s warranty refer to page 39 There are a number of factors that will affect the length of service t...

Страница 7: ...er heater off when it is not in use The thermostat is fully automatic and only allows the gas control to open when the burner requires gas for heating The thermostat may flash AH alarm high and the cu...

Страница 8: ...valve to each shower outlet to reduce water usage Pressure relief valve running Is the relief valve discharging too much water Refer to Pressure Relief Valve Running on page 9 Thermostat setting Ensu...

Страница 9: ...indicate the mains water pressure sometimes rises above the designed pressure of the water heater Ask your installing plumber to fit a pressure limiting valve WARNING Never replace the relief valve w...

Страница 10: ...failing Warning Exercise care to avoid any splashing of water as water discharged from the drain line will be hot Stand clear of the drain line s point of discharge when operating the valve s lever If...

Страница 11: ...ure relief valve may be supplied inside the water heater casing This kit must be removed before the water heater is operated READ THESE INSTRUCTIONS IN FULL INSPECTION OF EQUIPMENT Check the water hea...

Страница 12: ...ght diverter before changing direction The flue design and installation must comply with AS 5601 NOTE Reduction of the flue diameter or alteration to the draft diverter may void the water heater warra...

Страница 13: ...ase the base material MUST be solid and filled in e g if steel mesh decking is used a suitable plate material must be installed to fill in the perforations to prevent excessive drafts entering the wat...

Страница 14: ...ng kPa 700 550 700 550 Mechanical Heating kPa Minimum Supply Pressure System water temperatures up to 65 C kPa 70 70 System water temperatures above 65 C kPa 120 120 Maximum Supply Pressure with ECV f...

Страница 15: ...nches off before this valve or from another cold water line in the premises then a pressure limiting valve of an equal pressure setting may be required prior to the temperature limiting device REDUCIN...

Страница 16: ...ut kW 44 62 76 94 Propane Gas Input MJ h 185 261 323 396 Output kW 41 58 72 88 Electrical Rating 240 V 50 Hz Power W 50 50 50 50 Current A 0 21 0 21 0 21 0 21 Weight empty Kg 91 93 103 107 Flue Connec...

Страница 17: ...pipe work size and water heater water connections without allowing for friction loss which will occur Low water flow will cause damage to the water heater and system components GAS INLET The gas conne...

Страница 18: ...g to the connection on the inlet outlet header then screw the relief valve onto the other end of the elbow Seal the treads using Teflon tape never hemp A drain line must be installed in accordance wit...

Страница 19: ...stem should be provided with manual bleed points or fitted with automatic air vents The design of the system must be such that the water heater is provided with adequate water flow and pressure at all...

Страница 20: ...hermostat setting requirements with the householder or responsible officer Refer to Temperature Control on page 30 INTERMITTENT PUMP OPERATION For applications utilising intermittent pump operation an...

Страница 21: ...On Off models cannot be connected to a building management system CONTROL PANEL ACCESS To access the electrical enclosure Remove the Philips head screw from the bottom of the front panel Remove the fr...

Страница 22: ...CONNECTIONS ELECTRICAL 22 WIRING DIAGRAM ON OFF MODELS...

Страница 23: ...CONNECTIONS ELECTRICAL 23 WIRING DIAGRAM MODULATING MODELS...

Страница 24: ...PTION MECHANICAL HEATING SYSTEMS NOTE When connecting additional controls the relays and timers etc must be located in an additional enclosure NOT fitted within the water heater For outdoor installati...

Страница 25: ...ff type water heaters are fitted with a Honeywell SV9605 smart valve This gas control incorporates the ignition electronics and provides the gas supply to the pilot and main burners Modulating Models...

Страница 26: ...loose fitting long sleeved clothing or disposable overalls Wear gloves and eye protection Consult Occupational Health and Safety Authorities for any further information AFTER HANDLING Rinse any expos...

Страница 27: ...sure that the main gas isolation valve is closed OPERATIONAL CHECKS Turn on the water heater and circulation pump and verify the flow switch operation if fitted refer to To Turn on the Water Heater on...

Страница 28: ...at the inlet to the water heater Plug in the power supply cord at the power outlet Switch on the electrical supply at the power outlet to the water heater NOTE If the water heater is correctly instal...

Страница 29: ...label refer to Location of Controls on page 25 Turn off the water heater Replace the cap on the pressure regulator adjuster Disconnect the manometer and replace the pressure tap screw and washer Chec...

Страница 30: ...ach folder indicated by the relevant label just press the SET key once You can now scroll through the contents of each folder modify it or use its functions If you do not use the keyboard for over 15...

Страница 31: ...TEMPERATURE CONTROL 31...

Страница 32: ...at Cool mode HC H C H Ont Oft Delay time relay on dOn sec 0 250 0 Delay time relay off dOF min 0 250 0 dbi min 0 250 0 Delay time at start up OdO min 0 250 0 dis Key pad lock LOC y n n Password PA1 nu...

Страница 33: ...d in a well pocket fitted in the outlet header and senses the temperature of the water leaving the water heater The high limit temperature setting is adjusted by removing the front cover loosen one Ph...

Страница 34: ...ilot flame Yellow flames indicate some restriction of the combustion air openings or incorrect burner gas pressure setting A bright orange luminous flame is not normal and can cause sooting under prol...

Страница 35: ...elief valve In a scaling water supply calcium carbonate is deposited out of the water onto any hot metallic surface Where the saturation index exceeds 0 80 warranty does not apply to a copper heat exc...

Страница 36: ...36 This page is intentionally blank...

Страница 37: ...37 This page is intentionally blank...

Страница 38: ...38 This page is intentionally blank...

Страница 39: ...led site shall be the owner s responsibility 2 5 Where the water heater is installed in a position that does not allow safe or ready access the cost of that access including the cost of additional mat...

Страница 40: ...ish to make a claim under this warranty you need to a Contact Rheem on 131031 and provide owner s details address of the water heater a contact number and date of installation of the water heater or i...