29
Maintenance
MAINTENANCE SCHEDULE
Once a Month
•
Manually operate door. If it is unbalanced or binding, call a trained door systems
technician.
•
Check to be sure door opens and closes fully. Adjust limits and/or force if necessary
(see Adjustment Steps 1 and 2).
•
Repeat the safety reverse test. Make any necessary adjustments (see Adjustment Step
3).
Once a Year
•
Oil door rollers, bearings and hinges. The garage door opener does not require
additional lubrication. Do not grease the door tracks.
Care of Your Garage Door Opener
To prevent possible SERIOUS INJURY
or DEATH:
• NEVER allow small children near
batteries.
• If battery is swallowed, immediately
notify doctor.
To reduce risk of fi re, explosion or
chemical burn:
• Replace ONLY with 3V CR2032
coin batteries.
• DO NOT recharge, disassemble, heat
above 212° F (100° C) or incinerate.
NOTICE: To comply with FCC and or Industry Canada (IC)
rules, adjustment or modifications of this receiver and/or
transmitter are prohibited, except for changing the code
setting or replacing the battery. THERE ARE NO OTHER
USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR
OFFICE USE. Operation is subject to the following two
conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that may
cause undesired operation.
THE REMOTE CONTROL BATTERY
The LED(s) on your remote control will stop fl ashing when the battery is low and needs
to be replaced. To replace battery, open the case as shown. Insert battery positive side up
(+). Replace the battery with only 3V CR2032 coin cell batteries. Dispose of old battery
properly.
3V CR2032
Pry open the case first in the middle (1), then
at each side (2 and 3) with the visor clip.
1
2
3