background image

4

To prevent possible SEVERE INJURY or DEATH:
•   Install a LiftMaster Monitored Entrapment Protection (LMEP) 

device.

•   NEVER permit children to operate or play with door control 

push buttons or remote controls.

•   Activate door ONLY when it can be seen clearly, is properly 

adjusted and there are no obstructions to door travel.

•   ALWAYS keep door in sight until completely closed. NEVER 

permit anyone to cross the path of closing door.

BASIC PROGRAMMING

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

R27

AUX

ANT

^^^^

AUX

ANT

AUX ANT

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

SINGLE BUTTON REMOTE CONTROL

1

Press and release 
the LEARN button 
(LED will light).

2

Repeat steps 1 and 2 for additional remote controls.

REMOTE CONTROLS

Built in 315 MHz radio receiver permits as many as 20 Security

®

 remote controls or dip switch remote controls in any combination.

Press and hold the button on the remote control until the LED 
fl ashes rapidly, then release to complete programming (LED 
will go out).

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

R27

AUX

ANT

^^^^

AUX

ANT

AUX ANT

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

TO ERASE ALL REMOTE CONTROLS

1

Press and hold the 
LEARN button (over 
5 seconds) until the 
LED goes out. All 
programmed remote 
controls will be 
erased.

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

R27

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

R27

AUX

ANT

^^^^

AUX

ANT

AUX ANT

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

O

PEN

3-BUTTON REMOTE CONTROL TO OPERATE AS A WIRELESS 3-BUTTON CONTROL STATION

NOTE: 

The feature will use 3 of the 20 memory channels in the operator.

1

2

3

Press and hold 
the LEARN button 
(LED will light).

Press the desired 
button on the logic 
board (OPEN, 
CLOSE or STOP). 
Release both 
buttons.

Press and hold the desired button of the remote 
control until LED fl ashes rapidly, then release.

Repeat steps 1 through 3 to program additional buttons.

ATTENTION 

AVERTISSEMENT 

AVERTISSEMENT 

AVERTISSEMENT 

WARNING 

WARNING 

CAUTION 

WARNING 

WARNING 

PRECAUCIÓN 

ADVERTENCIA 

ADVERTENCIA 

ADVERTENCIA 

RADIO OPERATION

MODE

OPEN

CLOSE

STOP

REVERSE WHILE 

CLOSING

TTC RESET

B2

X

X

X

X

B2 with TTC

X

X (3-button remote)

X

X

X when open

C2

X

X

X

Содержание MT5011UCHB

Страница 1: ...Radio Receiver Built on Board 315 MHz Installation Date CONTACT INFORMATION MEDIUM DUTY LOGIC USER S GUIDE MH5011URCHB MH5011ULCHB MT5011UCHB MJ5011UCHB www Raynor com...

Страница 2: ...is released before reaching the close limit BASIC PROGRAMMING RECOMMENDED INSTALLATION B2 WIRING TYPE WITH MONITORED ENTRAPMENT PROTECTION DEVICE Momentary contact to open close and stop Open overrid...

Страница 3: ...Logic Board Electrical Box D14 LED LEARN 1 2 3 4 5 6 7 STOP CLOSE OPEN ALTERNATE INSTALLATION C2 WIRING TYPE WITHOUT MONITORED ENTRAPMENT PROTECTION DEVICE FACTORY DEFAULT Momentary contact to open an...

Страница 4: ...D OPEN CLOSE TTC LEARN 1 LMEP1 LMEP2 2 3 4 5 6 7 STOP CLOSE OPEN R27 AUX ANT AUX ANT AUX ANT D14 COM INTRLK STOP LED OPEN CLOSE TTC LEARN 1 LMEP1 LMEP2 2 3 4 5 6 7 STOP CLOSE OPEN TO ERASE ALL REMOTE...

Страница 5: ...3 4 5 6 7 STOP CLOSE OPEN R27 Every press and release of the STOP button will add 5 seconds to the Timer to Close Example 30 second TTC 6 presses of the STOP button D14 COM INTRLK STOP LED OPEN CLOSE...

Страница 6: ...Press CLOSE button The door should move in the close direction Release CLOSE button Door should stop if in C2 mode The door should continue closing if in B2 mode Press STOP button The door should stop...

Страница 7: ...f the emergency release handle Emergency disconnect will close TO DISCONNECT DOOR FROM OPERATOR TO RECONNECT DOOR ARM TO TROLLEY 1 1 2 3 Emergency Disconnect Door Arm To prevent possible SERIOUS INJUR...

Страница 8: ...hoist operation Refer to Model MJ instructions for emergency operation When the manual chain hoist sash chain is engaged electrical operation will not function 1 2 Keyhole Bracket EMERGENCY DISCONNEC...

Страница 9: ...dealer DOOR REVERSES UNEXPECTEDLY Entrapment protection device activated Verify photoelectric sensors are aligned If photoelectric sensors are aligned and operator still does not operate properly con...

Страница 10: ...10 OPERATOR NOTES...

Страница 11: ...Button SECURITY Remote Control Includes visor clip Wireless Single Push Button Control SECURITY Rugged composite housing Wireless controls cannot be used in place of hard wired controls 1 2 4 5 7 8 0...

Страница 12: ...d at the Open limit Input functions as Open input at all other times Also used with external radio controls 71 MLMOTION Door In Motion Provides dry contact and a terminal block with contacts switched...

Отзывы: