background image

27

^^

OPEN

CLOSE

O

STOP

CPS-EI

Monitored Sensing Edge Interface:

Requires 4-wire monitored sensing edge.

Antenna:

External kit for medium duty.

EXT-ANT

Medium Duty Angle Mounting Bracket:

Heavy-gauge steel bracket. May be welded. For 
use with MJ, MGJ, and MH operators.

10-9095

Commercial Protector System:

LiftMaster Monitored Entrapment Protection (LMEP) 
provides protection on doors up to 45' wide. 
NEMA-4 rated.

CPS-UN4

Commercial Protector System:

LiftMaster Monitored Entrapment Protection (LMEP) 
provides protection on doors up to 30' wide.

ENTRAPMENT PROTECTION DEVICES

ANTENNA

Mounting Brackets:

Angle mounting bracket, Painted steel, for MJ, MH, 
and MHS.

10-12360

MOUNTING BRACKETS

Antenna Extension Kit:

The antenna extension kit can be used with 
EXT-ANT for maximum radio receiver range.

86LM (15') 
86LMT (25')

CPS-U

40-34141-1

LMEP2

LMEP1

E1

E2

E3

E4

CPS-EI

FIELD MODIFICATION KITS

71MLSBC

Single Button Control:

Provides additional input for Single Button Control functionality. Input 
functions as Close input when the operator is stopped at the Open 
limit. Input functions as Open input at all other times. Also used with 
external radio controls.

71 MLMOTION

Door-In-Motion:

Provides dry contact and a terminal block with contacts switched to 
power an auxiliary device while the door is in motion. 

OPEN

CLOSE

OPEN

CLOSE

373LM

WPB3LM3

371LM

WPB1LM3

3-Button SECURITY

®

 Remote Control:

Includes visor clip.

Wireless 3 Button Control Station SECURITY

®

:

Rugged composite housing. (Wireless controls 
cannot be used in place of hard wired controls.) 

1-Button SECURITY

®

 Remote Control:

Includes visor clip.

Wireless Single Push Button Control SECURITY

®

:

Rugged composite housing. (Wireless controls cannot 
be used in place of hard wired controls.) 

1

2

4

5

7

8

*

0

3

6

9

#

333LM

WKP5LM3 (5 4-digit entry codes)
WKP250LM3 (250 4-digit entry codes)

3-Button Tri-Colored Dip Switch Remote Control:

Open/Close/Stop functionality. Includes visor clip.

Wireless Access Control Keypads SECURITY

®

:

Rugged composite housing. (Wireless controls 
cannot be used in place of hard wired controls.) 

2-Button Control Station:

Steel enclosure.

02-102

3-Button Control Station:

Steel enclosure.

02-103

Key Control Station:

Indoor flush mount, NEMA 1.

02-109

REMOTE CONTROLS 315 MHZ 

CONTROL STATIONS

LiftMaster offers a variety of

 SECURITY

®

 

Remote 

Controls for your application needs. Single to 4-Button, 
visor or key chain. Contact your authorized dealer.

 

Chain Tensioner:

For 1" shafts

71-6023 

71-6125 

Chain Tensioner:

For 1-1/2" shafts

For Jackshaft Type 

Operators

ACCESSORIES

CHAIN TENSIONERS

65ME1234

65ME110

Miller ME123 4-Wire Monitored Safety Edge:

For sectional or rolling doors.

Miller ME110 4-Wire Monitored Safety Edge:

For rolling grilles and counter shutters.

Содержание MJ5011UCHB

Страница 1: ...h Built in Radio Receiver 315 MHz Your model may look different than the model illustrated in this manual INTENDED FOR PROFESSIONAL INSTALLATION ONLY Visit www Raynor com to locate a professional inst...

Страница 2: ...ections 11 12 Install 3 Button Control Station 12 13 Setup Radio Antenna 13 14 ADJUSTMENT 15 Adjust the Limits 15 Adjust the Clutch 15 ENTRAPMENT PROTECTION 16 19 LiftMaster Monitored Entrapment Prote...

Страница 3: ...operating balanced and lubricated door An improperly balanced door may not reverse when required and could result in SEVERE INJURY or DEATH 3 ALL repairs to cables spring assemblies and other hardware...

Страница 4: ...ose feature allows the door to automatically close after a preset time only available with B2 wiring and a monitored entrapment protection device Wiring Types The functionality of the operator is base...

Страница 5: ...with Model MH only 7 19 18 26 cm 12 69 32 23 cm MOUNTING DIMENSIONS A Wall Mounting B Bracket Mounting rolling door 6 34 16 1 cm 12 15 30 86 cm 15 78 40 03 cm 18 87 47 93 cm 3 1 7 87 cm 3 25 8 26 cm 6...

Страница 6: ...on door setup OUTPUT FORCE 125 ft lbs sec OUTPUT RPM MJ 80 RPM MH 80 RPM LIMIT ADJUST Fully adjustable up to 14 door Max DUTY 12 Cycles per Hour Max 50 Cycles per Day Max DRIVE TRAIN Maintenance Free...

Страница 7: ...off to the side near the top of the door jamb Output Shaft PREPARING YOUR DOOR The manufacturer recommends 3 feet 91 4 cm of clearance in front of operator for serviceability Before you begin Disable...

Страница 8: ...or shaft and operator drive shaft is 12 15 inches WALL MOUNT SHELF OR BRACKET MOUNTING Door Shaft Operator Drive Shaft Door Shaft Operator Drive Shaft TYPICAL INSTALLATION NOTE The illustrations may n...

Страница 9: ...chain is taut not tight If chain is too tight it may cause damage to operator Keep door sprocket and operator door sprocket aligned If sprockets are not aligned they may cause premature wear on the ch...

Страница 10: ...chain wheel and through chain guide Secure chain retaining bracket to wall 4 feet above the floor Connect the ends of the hand chain Hand Chain Hand Chain Wheel Keyhole Bracket Chain Retaining Bracket...

Страница 11: ...e and clearly labeled ALL power and control wiring MUST be run in separate conduit WARNING POWER AND GROUND WIRING CONNECTIONS NOTE Power and control wiring must be run in separate conduit in accordan...

Страница 12: ...rom ALL moving parts of door Install the control station far enough from the door to prevent the user from coming in contact with the door while operating the controls Install the entrapment warning p...

Страница 13: ...l Common Locate the wire antenna on the outside of the electrical box Cut the wire tie closest to the edge of the electrical box Press the plastic standoff into the hole in the side of the electrical...

Страница 14: ...LY activate door when it can be seen clearly it is properly adjusted and there are no obstructions to door travel 4 Personnel should keep away from a door in motion and ALWAYS keep door in sight until...

Страница 15: ...Door Travel NOTE When retaining plate is released verify that the retaining plate is fully seated with the notches of the limit nut ADJUSTMENT 1 2 3 FOR MODELS MJ AND MH 1 2 3 4 Turn clutch nut to re...

Страница 16: ...TION LMEP Safety Reversing Sensor Invisible Light Beam Protection Area Safety Reversing Sensor Right Side of Garage Left Side of Garage Photoelectric Sensor 6 15 cm max above oor Invisible Light Beam...

Страница 17: ...re obstructions are cleared Tighten the nuts securely Inside Wall C Shaped Wrap Mounting Bracket with Square Holes 1 4 20x1 2 Carriage Bolts 1 4 Lock Nuts Drill 3 8 Holes Door Track ALTERNATE WALL INS...

Страница 18: ...lenses pointing toward each other across the door Attach the sensors to the brackets with the provided hardware Finger tighten the receiving sensor wing nut Securely tighten the sending sensor wing nu...

Страница 19: ...connections 10 Factory Wiring Connector Factory wiring harness connection ENTRAPMENT PROTECTION WIRING OPTIONS ENTRAPMENT PROTECTION AUX ANT AUX ANT D14 COM INTRLK STOP LED OPEN CLOSE TTC LEARN 1 LMEP...

Страница 20: ...d ON to reset wiring type Restricted close mode requires a constant pressure close command The operator will begin closing after a 5 second delay and will continue to close to the close limit switch T...

Страница 21: ...4 5 6 7 LMEP1 LMEP2 INTRLK COM STOP CLOSE OPEN STOP CLOSE OPEN AUX ANT Logic Board Electrical Box D14 LED LEARN 1 2 3 4 5 6 7 STOP CLOSE OPEN ALTERNATE INSTALLATION C2 WIRING TYPE WITHOUT MONITORED E...

Страница 22: ...STOP CLOSE OPEN SINGLE BUTTON REMOTE CONTROL 3 BUTTON REMOTE CONTROL TO OPERATE AS A WIRELESS 3 BUTTON CONTROL STATION NOTE The feature will use 3 of the 20 memory channels in the operator TO ERASE A...

Страница 23: ...door should move in the open direction Press STOP button The door should stop Press CLOSE button The door should move in the close direction Release CLOSE button Door should stop if in C2 mode The doo...

Страница 24: ...ctrical interlock will disable the electrical controls when the hoist is used Pull the disconnect chain sash chain to engage the hoist mechanism The disconnect chain may be locked in position by slipp...

Страница 25: ...g DOOR DRIFTS AFTER OPERATOR STOPS A Door not balanced properly Disconnect trolley assembly and check door for proper operation B Clutch slipping Adjust clutch see ADJUSTMENT section C Brake not funct...

Страница 26: ...ion Device failure Check for 1 Misaligned or blocked Photoelectric Sensors 2 Issue with Monitored Sensing Edge and or wiring 5 Incorrect motor direction Reverse the yellow and red motor wires on the c...

Страница 27: ...ary device while the door is in motion OPEN CLOSE OPEN CLOSE 373LM WPB3LM3 371LM WPB1LM3 3 Button SECURITY Remote Control Includes visor clip Wireless 3 Button Control Station SECURITY Rugged composit...

Страница 28: ...Operator 3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON 2 OR MORE KEY LOCKOUT 7 6 3 5 Stop Close Open Stop Close Open 7 6 3 5 Stop Close Open 2 BUTTON STATION OR...

Отзывы: