background image

16

Invisible Light Beam
Protection Area

Safety Reversing Sensor
6" (15 cm) max. above floor

Safety Reversing Sensor
6" (15 cm) max. above floor

Facing the door from inside the garage.

INSTALLATION STEP 10

Install The Protector System

®

The safety reversing sensor must be connected and 
aligned correctly before the garage door opener will 
move in the down direction.

IMPORTANT INFORMATION ABOUT THE SAFETY 
REVERSING SENSOR

When properly connected and aligned, the sensor will 
detect an obstacle in the path of its electronic beam. The 
sending eye (with an amber indicator light) transmits an 
invisible light beam to the receiving eye (with a green 
indicator light). If an obstruction breaks the light beam 
while the door is closing, the door will stop and reverse to 
full open position, and the opener lights will flash 10 times.

The units must be installed inside the garage so that the 
sending and receiving eyes face each other across the 
door, no more than 6" (15 cm) above the floor. Either can 
be installed on the left or right of the door as long as the 
sun never shines directly into the receiving eye lens.

The mounting brackets are designed to clip onto the track 
of sectional garage doors without additional hardware.

If it is necessary to mount the units on the wall, the 
brackets must be securely fastened to a solid surface such 
as the wall framing. Extension brackets (see Accessories) 
are available if needed. If installing in masonry 
construction, add a piece of wood at each location to 
avoid drilling extra holes in masonry if repositioning is 
necessary.

The invisible light beam path must be unobstructed. No 
part of the garage door (or door tracks, springs, hinges, 
rollers or other hardware) may interrupt the beam while 
the door is closing.

 Be sure power is not connected to the garage door opener 
BEFORE installing the safety reversing sensor.
 To prevent SERIOUS INJURY or DEATH from a closing garage 
door:
•  Correctly connect and align the safety reversing sensor. This 

required safety device MUST NOT be disabled.

•  Install the safety reversing sensor so beam is NO HIGHER 

than 6" (15 cm) above garage floor.

Содержание 3255RGD

Страница 1: ...l Please read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and pro...

Страница 2: ...r garage door opener 28 Having a problem 29 Diagnostic chart 30 Programming 31 32 To add or reprogram a hand held remote control 31 To erase all codes 31 3 Button remotes 31 To add reprogram or change...

Страница 3: ...lement Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or...

Страница 4: ...your installation Additional materials may be Access Door Safety Reversing Sensor Safety Reversing Sensor Slack in chain tension is normal when garage door is closed Gap between floor and bottom of d...

Страница 5: ...ol Visor Clip Door Bracket Multi Function Door Control Panel LOCK LIGHT The Protector System 2 Safety Reversing Sensors 1 Sending Eye and 1 Receiving Eye with 2 Conductor White White Black Bell Wire a...

Страница 6: ...nut on the trolley to obtain more chain slack Insert the second washered bolt CAUTION Use only the bolt previously removed from motor unit Tighten both bolts securely through the rail into the motor u...

Страница 7: ...e risk of SEVERE INJURY or DEATH WARNING WARNING WARNING WARNING 1 READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS 2 Install garage door opener ONLY on properly balanced and lubricated gara...

Страница 8: ...the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 9 for ceiling installation To prevent possible...

Страница 9: ...age Door Header Wall Garage Door UP CEILING MOUNT ONLY Wall Mounting Holes Optional Wall Mounting Holes The nail hole is for positioning only You must use lag screws to mount the header bracket UP CEI...

Страница 10: ...ll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket holes and join w...

Страница 11: ...enient for setting an ideal door to rail distance Remove foam packaging Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way a...

Страница 12: ...side of the motor unit to the structural support 2 Cut both pieces of the hanging bracket to required lengths 3 Drill 3 16 pilot holes in the structural supports 4 Attach one end of each bracket to a...

Страница 13: ...ire in several places Do not pierce wire with a staple creating a short or open circuit 4 Strip 7 16 11 mm of insulation from end of bell wire Connect bell wire to the quick connect terminals as follo...

Страница 14: ...hole in the release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the floor Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement Sec...

Страница 15: ...g cord Connect the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be ground...

Страница 16: ...15 cm above the floor Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the...

Страница 17: ...p hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 3 Place the bracket again...

Страница 18: ...lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct The sending eye amber indicator light will glow regardless of alignment or obstruction...

Страница 19: ...epending on your door s construction Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket Drill 3 16 fastening holes Secure the door bracke...

Страница 20: ...he door if required for your installation Refer to the dotted line optional placement drawing Self Threading Screw 1 4 14x5 8 HARDWARE SHOWN ACTUAL SIZE Header Wall Vertical Centerline of Garage Door...

Страница 21: ...re 3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Brin...

Страница 22: ...hers 5 16 Ring Fastener Straight Arm Bolts 5 16 18x7 8 Door Bracket Clevis Pin 5 16 x1 1 4 Curved Door Arm Press the Door Control push button The trolley will travel to the fully closed position Manua...

Страница 23: ...as explained in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won t...

Страница 24: ...ntrol clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount r...

Страница 25: ...bstruction and run the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY...

Страница 26: ...ight feature on the Multi Function Door Control is activated Bulb size is A19 Bulb power is 100 watts maximum SAFETY SIGNALTM light feature Lights will also turn on when someone walks through the open...

Страница 27: ...Wall Mounted Door Control THE MULTI FUNCTION DOOR CONTROL Press the push bar to open or close the door Press again to reverse the door during the closing cycle or to stop the door while it s opening...

Страница 28: ...or tracks NOTICE To comply with FCC and or Industry Canada rules IC adjustment or modifications of this receiver and or transmitter are prohibited except for changing the code setting or replacing the...

Страница 29: ...s to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment Step 1 Adjust the...

Страница 30: ...uch wires together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white terminals with jump...

Страница 31: ...1 Press and release the learn button on the motor unit The learn indicator light will glow steadily for 30 seconds 2 Within 30 seconds press and hold the button on the hand held remote that you wish t...

Страница 32: ...unit lights will blink once when the PIN has been learned Test by pressing the new PIN then press Enter The door should move To set a temporary PIN You may authorize access by visitors or service peop...

Страница 33: ...oor control panel 2 371RGD 1 Button remote control 3 10A20 3V2032 Lithium battery 4 29B137 Remote control visor clip 5 41A2828 Emergency release rope and handle assembly 6 41B4494 1 2 Conductor bell w...

Страница 34: ...s 8 30B532 Capacitor 1 2 HP 9 12A373 Capacitor bracket 10 41A3150 Terminal block with screws 11 41D3058 Universal replacement motor and bracket assembly Complete with Motor worm bracket bearing assemb...

Страница 35: ...ss Entry Enables homeowner to operate garage door opener from outside by entering a password on a specially designed keyboard Also can add a temporary password for visitors or service persons This tem...

Страница 36: ...med to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or replaced with...

Отзывы: