Problem
Possible causes
Possible solutions
Display brightness is set too low.
Use the brightness controls at the display to adjust accordingly.
The contrast or brightness settings in the
thermal camera application are set too
low.
Use the appropriate softkeys in the thermal camera application to adjust the
contrast and brightness of the image.
Image too dark or too light.
The Scene Mode is not appropriate for the
current conditions.
A particular environment may benefit from a different Scene Mode setting.
For example, a very cold background (such as the sky) could cause the
camera to use a wider temperature range than appropriate. Use the
SCENE
button.
Image freezes momentarily.
FFC (Flat Field Correction).
The image will pause momentarily on a periodic basis during the Flat Field
Correction (FFC) cycle. Just prior to the FFC, a small green square will
appear in the upper left corner of the screen.
Image is inverted (upside down).
Camera “Ball down” setting is incorrect.
Ensure that the Ball down setting within the thermal camera system setup
menu is set correctly.
34
T-Series thermal cameras – Operation and setup