Chapter 2, ST40 Depth Instrument
ST40 Instruments Service Manual 83149-2
2-11
E22038
When entering self test stage 3, the instrument beeps and the display shows
TEST3
,
for 1 second.
A transducer test then starts. If the interface is working correctly,
PASS
is displayed.
If the test fails,
FAIL 43
is displayed. Use the following table to try to isolate the cause.
Check
Failure mode
Action
Pulses at IC5, pins 1 & 4
No pulses
Check R113
Check IC5 and replace if suspect
Check for dry joints at IC6 pins 46 & 49.
Pulses at TR4 drain
No pulses
Check R123
Pulses at TR8 drain
No pulses
Check R124
Pulses at DEPTH+ & DEPTH-
No pulses
Check TR4, TR8 & T1
Depth receiver output pulses
No pulses
Return instrument to Raymarine Ltd.
at IC4, pin 14
Press the
and
keys together momentarily to exit self-test.