background image

10

Software

Software history

Software upgrade

The Type S1(G) Course Computer has the ability to implement software upgrades via the NMEA port connected to a PC 
running Windows 9x or NT 4.0. This section describes the upgrade procedure.
A PC or laptop with an RS232 port is required, together with a custom serial download cable.
The laptop software comprises three files plus the downloadable file.

Note: 

It is very important that during the actual file transfer that power is not removed from the Course Computer. If power 

is lost, only a partial transfer will take place and will render the unit inoperable.   In this case the unit will have to be returned 

to Raymarine.

            

Download procedure

1. Power Off the Course Computer and connect a cable as shown to the PC's serial port. 
2. From the PC, run the programme 

SWDL 4 Windows.exe.

3. From the menu select 

File>Open

 

CC115K1.INI

 if using com port 1

 or

 

CC115K2.INI

 if using com port 2.

4. Power Up the Course Computer. You should now see RED and BLACK messages on the scrolling down the screen.

Version

Change

3.04

Fixes loss of calibration items

RS232 connections

RS232

SmartPilot computer terminals

Screen

Blue

Red

Yellow

Green

Screen

Blue

Red

Green

Red

Yellow

Screen

Red

Yellow

Screen

Red

Yellow

Screen

S

eaTalk

S

eaTalk

CLUTCH

NMEA

RUDDER

RATE GY RO

FLUXGATE

1 2 3 4 5

9

8

7

6

Pin 2 Rx
Pin 3 Tx
Pin 5 GND

D8592-1

Содержание SmartPilot S1

Страница 1: ...SmartPilot S1 S1G Service Manual Document number 83183 1 Nov 05 ...

Страница 2: ...egistered Trademark of Teleflex Incorporated BayStar is a Trademark of Teleflex Incorporated NMEA is a Registered Trademark of the National Marine Electronics Association All other trademarks used in this document are acknowledged Copyright Raymarine UK Ltd 2005 ...

Страница 3: ...tion 6 Equipment and tools 6 Initial inspection checks 6 Rate gyro connection 6 Detailed diagnosis 6 Step 1 Power checks 6 Step 2 System checks 7 Step 3 Rate gyro 7 Step 4 Compass 7 Step 5 Rudder Reference 8 Step 6 Clutch Auto 8 Step 7 Clutch Standby 8 Step 8 H Bridge 8 Step 9 NMEA 8 Step 10 EEPROM Test 8 Disassembly and reassembly 9 Tools required 9 Disassembly reassembly 9 Software 10 Software h...

Страница 4: ...2 ...

Страница 5: ...e equipment and accessories are designed to the best industry standards for use in the recreational marine environment The design and manufacture of Raymarine equipment and accessories conform to the appropriate Electromagnetic Compatibility EMC standards but correct installation is required to ensure that performance is not compromised Waste Electrical and Electronic WEEE Directive TheWEEEDirecti...

Страница 6: ...atusingthedrive unit The Course Computer assembly consists of a plastic case a printed circuit board PCB The PCB carries a microprocessor electroniccircuitrytocontrolthedriveunit apoweramplifierforthedrivemotorandaconnectorblockfor all inputs and outputs Type S1G assembly drawing 1 2 3 6 7 5 4 D8595 1 Item Description 1 Rate giro Murata 2 Ring ferrite 3 Connector cover 4 Housing 5 Fuse Power in 15...

Страница 7: ...5 Spares Item Spare Accessory Part Number Comments 3 4 Connector cover Housing 5 7 Fuse 15 A Fuse 2 A 6 PCB less gyro 1 Gyro A18069 Kionix from Aug 2005 Revision E PCBs ...

Страница 8: ...t see Tech Update TU228 on page 14 4 Check that resistance value of R18 matches the requirement of the gyro fitted see Tech Update 332 on page 16 Rate gyro connection The plug is designed to fit one way into the socket Check the plug is correctly inserted and fully seated Detailed diagnosis Before starting testing ensure that the following are connected to the Course Computer Fluxgate compass Rudd...

Страница 9: ...e direction and decrease from 2 5V as it is turned in the opposite direction If the signal levels are unstable or outside tolerances replace the gyro Refer to Tech Update TU232 Step 4 Compass 1 With the compass unit connected to the Course Computer rotate the compass through 90º as shown below 2 Slowly rotate the compass clockwise through 360º As the compass is turned check that the displayed head...

Страница 10: ...roceed to Step 7 Step 7 Clutch Standby 1 Press STANDBY 2 Measure voltage at clutch terminals If the voltage is 0 V proceed to Step 8 Step 8 H Bridge 1 Press AUTO 2 Press 10 twice the motor should spin 3 Press STANDBY the motor should stop 4 Press AUTO 5 Press 10 twice the motor should spin in the opposite direction 6 Measure HD PWR whilst the motor is running Check this against the table in Step 1...

Страница 11: ...perly equipped anti static station by personnel wearing anti static straps Tools required To assemble disassemble the Course Computer you will need 3 mm Allen key cross head screwdriver Disassembly reassembly Remove the connector cover Remove the PCB retaining screw Slide out the PCB Unplug the rate gyro connector from the PCB Remove the gyro retaining screws on the rear of the PCB retain the scre...

Страница 12: ...rtheunitinoperable Inthiscasetheunitwillhavetobereturned to Raymarine Download procedure 1 Power Off the Course Computer and connect a cable as shown to the PC s serial port 2 From the PC run the programme SWDL 4 Windows exe 3 From the menu select File Open CC115K1 INI if using com port 1 or CC115K2 INI if using com port 2 4 Power Up the Course Computer You should now see RED and BLACK messages on...

Страница 13: ...e dialog box select BIN file required for download CAUTION DO NOT SWITCH OFF POWER TO THE COURSE COMPUTER DURING THE FILE DOWNLOAD 8 The Download will take 30 seconds to 1 min and the message Download Successful will be displayed 9 Power OFF the Course Computer and disconnect the download cable 10 The software upgrade is now complete and the Course Computer is ready for use ...

Страница 14: ...12 Product history Technical updates Update Title TU228 Fluxgate Compass Circuit Fault TU232 Introduction of new Kionix Rate Gyro module ...

Страница 15: ...r correctly orientated Ref Tech note TU232 resistor value 113k Kionix gyro Ref Tech note TU232 resistor value 110k Murata gyro Ref Tech note TU228 capacitor incorrectly orientated PCB 3015 286 issue E Aug 05 PCB 3015 286 issue A to E ...

Страница 16: ...highlighted a potential fluxgate compass circuit fault which can affect current S1 and S1G SmartPilot course computers The fault will cause the compass heading to drift jump segments or show large inaccuracies The fault is associated with the wrongly reverse placement of the fluxgate drive AC coupling capacitor C43 The fault does not affect all S1 Course Computers and is only triggered when the to...

Страница 17: ...2 of 2 Service Details and Procedures C43 Polarised Capacitor 2 2uF 6 3v Wrongly Placed on PCB Service Procedure x Remove PCB from plastic casing x Locate C43 Capacitor x Unsolder Remove from PCB x Replace re solder in reverse Correctly Placed C43 ...

Страница 18: ...s Product Description SmartPilot S1G S2G S3G Serial Number s S1G E12115 0850001 S2G E12091 0850001 S3G E12092 0850054 S3G IPS E12177 0850003 Subject Introduction of new Kionix Rate Gyro module Due to obsolescence of the earlier Murata type Gyro a new Rate Gyro module Kionix has now been introduced into production SmartPilot Course Computers The list above indicates start serial numbers Improved hi...

Страница 19: ...yro on early Course Computer PCB S1G Replace R18 with 113K Resistor secure and connect Gyro as above S2G S3G 150G 400G Replace R145 R147 with 11 3K Resistor secure and connect Gyro as above Replacing faulty Course Computer PCB with new modified PCB and retaining early Murata Gyro S1G Replace PCB and change R18 with 100K Resistor secure and connect Gyro as above S2G S3G 150G 400G Replace PCB and ch...

Страница 20: ...18 ...