Raymarine Remote Keypad Скачать руководство пользователя страница 22

16

SeaTalk Remote Keypad Owner’s Handbook

8.

When all groups have been defined and all Remote Keypads
allocated, simultaneously press the middle two 

 keys of the

bottom row for 1 second, to return to group setup mode, then
simultaneously press the middle two 

 keys for a further 2

seconds to return to normal operation.

4.3 Grouping ST80 MaxiView instruments

To define a group of ST80 MaxiView instruments:

1.

At any Remote Keypad, press and hold the upper 

 and 

keys for 4 seconds. All the ST80 MaxiView instruments enter
group setup mode. On one of the instruments, the display will
change to reverse video and the cursor will flash.

2.

Select the first instrument in the group using the 

 and 

 keys.

3.

Referring to the following illustration, use the appropriate keys to
allocate a group letter and sequence number to the selected
instrument. When the instrument has been properly identified, it
should display its group letter and sequence number, e.g. 

J2

.

Select the required MaxiView instrument

Select either:

group setup or

sequence number setup

(toggle action)

Press to set the identity you want, either:

J to Q for group identity, or

1 to 8 for instrument sequence number

D2359-2

Note: In group setup mode, all ST80 MaxiView instruments are
selectable.

4.

Press the 

 key to select another instrument and repeat the

procedure in step 3.

5.

Repeat the procedure in steps 3 and 4 until all instruments in the
group have been identified.

Note: If you have more than eight ST80 MaxiView instruments, a
second group, operated by another remote keypad, must be created.
The identification code for additional keypads and instruments would,
for example, be 

K1

K2 

etc.

073_5txt.p65

1/22/2003, 10:07 AM

16

Содержание Remote Keypad

Страница 1: ...SeaTalk Remote Keypad Owner s Handbook Document number 81073_5 Date 1February 2003...

Страница 2: ...Copyright Raymarine Limited 2003...

Страница 3: ...hapter 2 Maintenance Fault Finding 5 2 1 Maintenance 5 Servicing and safety 5 Cabling 5 Assistance 5 2 2 Fault finding 5 Chapter 3 Installation 7 3 1 Planning your installation 7 EMC installation guid...

Страница 4: ...SeaTalkRemoteKeypadOwner sHandbook Chapter 4 Setup 13 2 1 Introduction to instrument grouping 13 2 2 Grouping standard instruments 13 2 2 Grouping ST80 MaxiView instruments 16 Chapter 5 Specification...

Страница 5: ...teKeypadOwner sHandbook iii Package Contents 1 Remotekeypad 5 SeaTalkcable 2 Thumbnuts 2 6 Installationtemplate 3 Fixingstuds 2 7 Owner sHandbook thisbook 4 Suncover 8 QuickReferenceGuide D4545 3 3 2...

Страница 6: ...iv SeaTalkRemoteKeypadOwner sHandbook...

Страница 7: ...ts Agroupoffourkeys usedtocontrolST80MaxiViewinstruments D1945 6 Controls for MaxiView instruments Controls for standard instruments SeaTalk Remote Keypad Instrumentscanbeorganisedingroups uptoamaximu...

Страница 8: ...t groups Port steering station SeaTalk link Starboard steering station 120 120 60 60 90 90 30 30 Port and starboard steering stations on a catamaran Flybridge and cabin steering stations on a power ve...

Страница 9: ...ected ST80 MaxiView Cycle pages in selected ST80 MaxiView chapter Select required standard instrument These four keys duplicate the functions of the respective keys on the selected standard instrument...

Страница 10: ...ndtheabilityto remotelycontroltheinstrumentissuspended untilyouagainpressa remotekeytore displaytheremoteindication D2354 2 ST60 ST80 Typical remote indications 1 3 General information TheRemoteKeypad...

Страница 11: ...rhandlethe cables connectorswhenpowerisbeingsuppliedtotheequipment AlwaysreportanyEMCrelatedproblemtoyournearestRaymarine dealer Wewilluseanysuchinformationtoimproveourquality standards Cabling Period...

Страница 12: ...ifitis damaged Instrumentsdonotoperateinalogicalsequence Instrumentsandkeypadarenotgrouped Referto Chapter 4 Setup chapterforgroupingdetails All instruments operate at the same time Instrumentsarenotg...

Страница 13: ...ethattheywillperform underallconditions itisimportanttounderstandwhatfactorscould affecttheoperationoftheproduct Tominimisetheriskofoperatingproblems All Raymarine equipment and cables connected to it...

Страница 14: ...oother equipmentusingacablenotsuppliedbyRaymarine asuppression ferriteMUSTalwaysbefittedtothecableclosetotheRaymarineunit Tools 5mmtwistdrill 45mm 1 77in tankcutter holesaw Powerdrill Screwdrivers Sit...

Страница 15: ...eKeypadasfollows 1 Applythefittingtemplate suppliedneartherearofthishandbook totheintendedlocation usingadhesivetapeifnecessary Markthe centresforthefixingstudclearanceholes 2 andtheaperture 3 forther...

Страница 16: ...eypadas shown 8 Fitthekeypadtothebulkhead byinsertingthefixingstuds 1 throughthedrilledholes 2 andsecuringwiththethumbnuts 5 TightenthethumbnutsBYHAND untilthekeypadissecure Do NOTuseawrenchtotightent...

Страница 17: ...yhead installationchapterforalistofoptions 3 3 Check before going to sea EMC conformance Alwayschecktheinstallationbeforegoingtoseatomakesurethatit isnotaffectedbyradiotransmissions enginestartingetc...

Страница 18: ...12 SeaTalkRemoteKeypadOwner sHandbook...

Страница 19: ...canhaveuptoeightinstruments EachgroupmusthaveatleastoneRemoteKeypadgroupedtoit EachRemoteKeypadcanonlybegroupedwithoneST80 MaxiViewandonestandardinstrumentgroup Eachinstrumentinagrouphasauniquealphanu...

Страница 20: ...e or keytoselectainstrumenttobethefirstinthe group 3 Referringtothefollowingillustration usetheappropriatekeysto allocateagroupletterandsequencenumbertotheselected instrument Whentheinstrumenthasbeenp...

Страница 21: ...ypadtotherequiredgroupasfollows a Usethe or keytoselectanyinstrumentintherequired group b Pressthe and keystogetherfor1second Depending onthetypeofinstrumentsyouaregrouping thefollowing messagesaredis...

Страница 22: ...eappropriatekeysto allocateagroupletterandsequencenumbertotheselected instrument Whentheinstrumenthasbeenproperlyidentified it shoulddisplayitsgroupletterandsequencenumber e g J2 Select the required M...

Страница 23: ...GROUPis displayed c AttheRemoteKeypad presseitherthe orthe key to assigntheRemoteKeypadtotheselectedinstrumentgroup 7 Ifyouarecreatingmorethanonegroup repeattheprocedures describedinsteps2to6 8 Whenal...

Страница 24: ...18 SeaTalkRemoteKeypadOwner sHandbook...

Страница 25: ...9 Chapter5 Specification Dimensions 110 mmx68 mmx17 mm 4 33 x 2 67 x 0 66 in Powersupply 10 V to 16 V dc Currentconsumption 90mAto190 mA illuminationfullon Operatingtemperature 10 Cto 70 C 14 Fto158 F...

Страница 26: ......

Страница 27: ...Drill 5mm 3 16 TOP Drill 5mm 3 16 Machine 45mm 13 4 Datum Line for Instrument Keypad alignment D2558 2 SeaTalk Remote Keypad Fitting Template...

Страница 28: ...22 SeaTalkRemoteKeypadOwner sHandbook...

Отзывы: