Connecting power
When connecting power, refer to the
Planning
section and:
• Ensure that the total length of power cable will not exceed the
maximum length, as described under
Power cable lengths
.
• Connect power only via the correct value thermal breaker or fuse,
as described under
Power Supply Protection
.
Caution: Do NOT connect to positive
ground system
Do NOT connect this product to a
positively-grounded system.
Connection procedure
Connect the power cable part of the digital cable to either a 12 V or
24 V dc supply, as follows:
1. Red wire to the ve, either at the output of the battery
isolator switch or at a dc distribution panel.
2. Black wire to battery negative.
3. Drain connection (screen) to the common ground point (see
Grounding
)
Sharing a breaker
Where more than 1 piece of equipment shares a breaker you must
provide protection for the individual circuits. E.g. by connecting an
in-line fuse for each power circuit.
D1
1637-1
+VE bar
Circuit breaker
Fuse
Fuse
-VE bar
Where possible, connect individual items of
equipment to individual circuit breakers.
Where this not possible, use individual in-line
fuses to provide the necessary protection.
24
HD Digital Radome User’s Guide
Содержание RD418HD
Страница 1: ...Raymarine HD Digital Rad ome Antenna User s Guide HD Digital Radome User s Guide ...
Страница 2: ......
Страница 4: ......
Страница 6: ...6 HD Digital Radome User s Guide ...
Страница 10: ...10 HD Digital Radome User s Guide ...
Страница 26: ...26 HD Digital Radome User s Guide ...
Страница 34: ...34 HD Digital Radome User s Guide ...
Страница 35: ......
Страница 36: ...www raymarine com ...