2. You can also use a DeviceNet to SeaTalkng ® adaptor cable (not supplied) to connect your
product to an available spur on your SeaTalkng ® backbone.
3.
Alternatively you can connect your product to a NMEA 2000 backbone using a standard
DeviceNet cable (not supplied).
Refer to
for a list of available SeaTalkng ® cables.
Note:
1.
The product must be connected to a correctly terminated backbone.
2. You cannot connect your product directly to a MFD.
3.
Refer to the instructions supplied with your SeaTalkng ® / NMEA 2000 device for details on
creating a backbone.
Connecting SeaTalkng ® cables
1. Rotate your product’s SeaTalkng ® connector locking collar counter clockwise, so that the
connector is in the unlocked position.
2. Ensure the cable’s connector is correctly oriented (groove pointing up).
3. Fully insert the cable connector..
4. Rotate the locking collar clockwise (2 clicks) until it is in the locked position.
56