4. Select
Yes
.
Your unit will now reset itself to factory default settings.
6.3 System data troubleshooting
Aspects of the installation can cause problems with the data shared between connected equipment.
Such problems, their possible causes and solutions are described here.
Transducer, instrument, engine or other system data is unavailable at all displays.
•
Data is not being received at the display.
1.
Check the relevant product and or network cabling and connections (e.g. SeaTalkng
backbone) for signs of damage or corrosion, and replace if necessary.
•
Data source (e.g. instrument display or engine interface) is not operating.
1.
Check the source of the missing data (e.g. transducer or engine interface) for signs of damage
or corrosion, and replace if necessary.
2. If possible, check that the data source is correctly powered and operational.
3.
Refer to the instructions provided with the equipment to ensure it has been correctly installed.
•
Software mismatch between equipment may prevent communication.
1.
Ensure all products have the latest software installed.
Transducer, instrument or other system data is missing from some but not all displays.
•
Connection problem.
1.
Check the product’s SeaTalkng spur cable and connections for signs of damage or corrosion,
and replace if necessary.
•
Software corruption.
1.
In the unlikely event that the product’s software has become corrupted, try downloading and
installing the latest software from the Raymarine website. refer to your Multifunction Display’s
operation instructions for details on updating software for SeaTalkng devices.
2. In the case of a restart loop attempt a factory reset using the following instructions:
p.40 — Performing a Factory Reset
•
Software mismatch between equipment may prevent communication.
1.
Ensure all products have the latest software installed.
Incorrect data reported.
• Transducer calibration error
1.
Switch off power supply to system and switch back on again.
2. Re-calibrate or re-configure data source following instructions provided with the relevant
devices.
6.4 Miscellaneous troubleshooting
Miscellaneous problems and their possible causes and solutions are described here.
Display behaves erratically.
Frequent unexpected resets or system crashes and other erratic behavior:
•
Intermittent problem with power to the display.
1.
Check relevant fuses and breakers.
2. Check that the power supply cable is sound and that all connections are tight and free from
corrosion.
3.
Check that the power source is of the correct voltage and sufficient current.
•
Software mismatch between equipment may prevent communication.
1.
Ensure all products have the latest software installed.
•
Corrupt data / other unknown issue.
System checks and troubleshooting
41