20
Installing the Transducer Cable –
Installation with Separate Speed and Temperature Sensors
1.
Optional
depth
-
only
and
speed
-
and
temperature
-
only
transducers
are
available for the FishFinder L365. In this optional configuration the
separate transducers are connected via a “Y” type receptacle cable
located on the optional speed- and temperature-only transducer cable.
2.
Plug the cable from the depth-only transducer into the receptacle
connector on the optional speed- and temperature-only transducer.
The speed- and temperature-only transducer then connects at the
transducer receptacle of the FishFinder L365. This is shown below in
Fig. 2-15.
Making the DC Power Connections
1.
The display unit is designed for use on boats with 12V DC power
systems. (The unit can operate as long as the DC voltage is between
11.0 and 16V DC.) The display unit can be wired to a negative-ground
system, or both the negative and positive supply lines may be “floating”
above ground.
This unit is not intended for use on boats with
positive ground.
Fig. 2-15
Cable for Speed
and Temperature
Sensor
Installation
Sensor for
depth only
Sensor for
speed and
temperature