LED color
LED code
Status
User action
Amber 6
blinks
Over voltage
(>34.2V)
• Ensure power supply levels are consistent with
recommendations.
• If problem persists contact Raymarine technical support.
Red 1 blink
General failure
• If combined with voltage warning, check power supply and
cables.
• Power cycle unit to recover.
• If problem persists contact Raymarine technical support.
Red 2 blinks
Not Defined
• If problem persists contact Raymarine technical support.
Red 3 blinks
Ambient temperature
too hot
• Ensure installation environment is within recommendations.
• Unit will recover when temperature falls within specifications.
• If problem persists contact Raymarine technical support.
Red 4 blinks
Problems with
internal database
• Power cycle unit to recover.
• If problem persists contact Raymarine technical support.
Note:
During a software upgrade process the LED will be solid Red and change to solid Amber on successful completion. A power cycle
will be necessary to install the changes.
Note:
If any other LED sequence other than described above is seen and persists please contact Raymarine technical support.