LED
color
LED code
Status
User action
Amber
7 blinks
*Problem
reading
transducer
ID (XID)
• Ensure transducer cable and
connections are secure and free
from damage.
• Power cycle unit to recover
transducer information.
• If problem persists contact Raymarine
technical support.
Red 1
blink
General
failure
• If combined with voltage warning,
check power supply and cables.
• Power cycle unit to recover.
• If problem persists contact Raymarine
technical support.
Red 2
blinks
Not Defined • If problem persists contact Raymarine
technical support.
Red 3
blinks
Ambient
tempera-
ture too hot
• Ensure installation environment is
within recommendations.
• Unit will recover when temperature
falls within specifications.
• If problem persists contact Raymarine
technical support.
Red 4
blinks
Problems
with internal
database
• Power cycle unit to recover.
• If problem persists contact Raymarine
technical support.
Note:
*Not applicable to CP370.
Note:
During a software upgrade process the LED will be solid Green and change to blinking
Green on successful completion.
Note:
If any other LED sequence other than described above is seen and persists please contact
Raymarine technical support.