background image

Chapter 10: Options and accessories

Chapter contents

10.1 Spares and accessories on page 44

10.2 Network hardware on page 44

10.3 Network cable connector types on page 45

10.4 Network cables on page 45

10.5 SeaTalk

ng

cables and accessories on page 46

Options and accessories

43

Содержание CP100

Страница 1: ...CP100 Installation instructions English Date 07 2013 Document number 87194 1 EN 2013 Raymarine UK Limited...

Страница 2: ......

Страница 3: ...s patents pending or design patents pending Fair Use Statement You may print no more than three copies of this manual for your own use You may not make any further copies or distribute or use the manu...

Страница 4: ......

Страница 5: ...4 5 Network connection 23 Chapter 5 Location and mounting 25 5 1 Selecting a location 26 5 2 Product dimensions 26 5 3 Mounting 27 Chapter 6 System checks and troubleshooting 29 6 1 Initial power on...

Страница 6: ...6 CP100...

Страница 7: ...alidate the European CE mark Caution Service and maintenance This product contains no user serviceable components Please refer all maintenance and repair to authorized Raymarine dealers Unauthorized r...

Страница 8: ...uct ownership please visit www raymarine com and register online It is important that you register your product to receive full warranty benefits Your unit package includes a bar code label indicating...

Страница 9: ...nd product information Chapter contents 2 1 Handbook information on page 10 2 2 Product overview on page 10 2 3 CHIRP Sonar overview on page 11 2 4 CHIRP DownVision overview on page 11 Handbook and pr...

Страница 10: ...nsducer 87197 88024 CPT 110 CPT 120 Through hull transducer Installation instructions Installation of a DownVision through hull transducer 87201 88025 New a Series c Series e Series Installation and o...

Страница 11: ...transducer and builds up a detailed underwater view The transducer sends pulses of sound waves into the water and measures the time it takes for the sound wave to travel to the bottom and back The re...

Страница 12: ...12 CP100...

Страница 13: ...on checklist on page 14 3 2 Parts supplied on page 14 3 3 Required additional components on page 15 3 4 Compatible multifunction displays on page 15 3 5 Compatible transducers on page 16 3 6 Typical s...

Страница 14: ...Secure all equipment in place 8 Power on and test the system Schematic diagram A schematic diagram is an essential part of planning any installation It is also useful for any future additions or maint...

Страница 15: ...3 4 Compatible multifunction displays for a list of compatible products Data cables Refer to Chapter 4 Cables and connections for suitable cables Some installations may also require extensions to dat...

Страница 16: ...ypical systems Example basic sonar system featuring multifunction display D12937 1 1 4 2 3 Item Description Part number 1 Multifunction display Refer to your dealer for all compatible variants 2 Sonar...

Страница 17: ...CU Refer to your dealer for all applicable part numbers 8 SeaTalkng spur cable Refer to 10 5 SeaTalkng cables and accessories 9 Evolution EV Refer to your dealer for all applicable part numbers 10 Pil...

Страница 18: ...18 CP100...

Страница 19: ...tions Chapter contents 4 1 General cabling guidance on page 20 4 2 Connections overview on page 20 4 3 Power connection on page 21 4 4 Transducer connection on page 22 4 5 Network connection on page 2...

Страница 20: ...dequate strain relief is provided Protect connectors from strain and ensure they will not pull out under extreme sea conditions Circuit isolation Appropriate circuit isolation is required for installa...

Страница 21: ...aTalkng backbone To avoid possible damage to equipment do NOT use a SeaTalkng backbone as the power source for this product Power cable extension The product is supplied with a power cable which can b...

Страница 22: ...uct is designed for use with DownVision transducers Refer to 3 5 Compatible transducers for a list of compatible transducers Transducers must be installed in accordance with the instructions provided...

Страница 23: ...n depending on variant The network connection method remains the same for all products featuring RayNet connectors Item Description 1 Sonar module 2 Connector panel for compatible Raymarine multifunct...

Страница 24: ...24 CP100...

Страница 25: ...Chapter 5 Location and mounting Chapter contents 5 1 Selecting a location on page 26 5 2 Product dimensions on page 26 5 3 Mounting on page 27 Location and mounting 25...

Страница 26: ...location for the unit consider the following points to ensure reliable and trouble free operation Access there must be sufficient space to enable cable connections to the unit avoiding tight bends in...

Страница 27: ...4 holes at the marked location on the template 108 2 mm 4 26 in 188 0 mm 7 40 in 34 6 mm 1 36 in 276 8 mm 10 90 in 299 4 mm 11 78 in Pilo t hol e cen ter 4 pos ition s CS 22 Te mplate UP IM PO RTAN T...

Страница 28: ...28 CP100...

Страница 29: ...ntents 6 1 Initial power on test on page 30 6 2 Software updates on page 30 6 3 Troubleshooting on page 31 6 4 Sonar troubleshooting on page 32 6 5 LED indications on page 33 6 6 Resetting the sonar m...

Страница 30: ...Sounder External sonar modules should be turned off at the power supply 2 Wait for the No Sounder Source Available message to be displayed in the Fishfinder application 3 Power on the new sonar module...

Страница 31: ...and shipping subjected to comprehensive test and quality assurance programs However if you experience problems with the operation of your product this section will help you to diagnose and correct pro...

Страница 32: ...support Gain or Frequency settings may be inappropriate for present conditions Check the sonar presets gain and frequency settings Unit power supply fault Check the voltage from the power supply if t...

Страница 33: ...d free from damage Ensure power supply cabling is consistent with recommendations If problem persists contact Raymarine technical support Amber 6 blinks Over voltage 34 2V Ensure power supply levels a...

Страница 34: ...isplay to restore the sonar module to its factory default settings In the fishfinder application 1 Select Menu 2 Select Set up 3 Select Sounder Set up 4 Select Sonar Reset 5 Select Yes to confirm or N...

Страница 35: ...Chapter 7 Maintenance Chapter contents 7 1 Routine checks on page 36 7 2 Unit cleaning instructions on page 36 7 3 Transducer care and cleaning on page 37 Maintenance 35...

Страница 36: ...ntains high voltage Adjustments require specialized service procedures and tools only available to qualified service technicians There are no user serviceable parts or adjustments The operator should...

Страница 37: ...e Transducers with a temperature sensor may not work properly if painted Note Never use ketone based paint Ketones can attack many plastics possibly damaging the sensor Note Never use spray paint on y...

Страница 38: ...38 CP100...

Страница 39: ...Chapter 8 Technical support Chapter contents 8 1 Raymarine customer support on page 40 8 2 Viewing product information on page 40 Technical support 39...

Страница 40: ...duct support raymarine com In Southeast Asia and Australia Tel 61 0 29479 4800 E mail aus support raymarine com Product information If you need to request service please have the following information...

Страница 41: ...Chapter 9 Technical specification Chapter contents 9 1 Technical specification on page 42 Technical specification 41...

Страница 42: ...ies Sonar Centered 200 KHz DownVision Centered 350 KHz Beam coverage Sonar 25 conical beam DownVision Wide port starboard and thin fore aft fan beam Target separation Achieved through CHIRP processing...

Страница 43: ...pter contents 10 1 Spares and accessories on page 44 10 2 Network hardware on page 44 10 3 Network cable connector types on page 45 10 4 Network cables on page 45 10 5 SeaTalkng cables and accessories...

Страница 44: ...eaturing RayNet connectors Equipment with RJ45 SeaTalkhs connectors can also be connected via suitable adapter cables RJ45 SeaTalkhs network switch E55058 8 port switch for network connection of multi...

Страница 45: ...et cable female A80005 10 m 32 8 ft RayNet to RayNet cable female A62362 20 m 65 6 ft RayNet to RayNet cable female A80006 50 mm 1 97 in RayNet to RayNet cable male A80162 RayNet right angled coupler...

Страница 46: ...aTalkng Terminator A06031 SeaTalkng T piece A06028 Provides 1 x spur connection SeaTalkng 5 way connector A06064 Provides 3 x spur connections SeaTalkng backbone extender A06030 SeaTalk to SeaTalkng c...

Страница 47: ......

Страница 48: ...www raymarine com...

Отзывы:

Похожие инструкции для CP100