• Ideally, all equipment should be wired to individual suitably-rated thermal breakers or fuses, with
appropriate circuit protection. Where this is not possible and more than 1 item of equipment shares
a breaker, use individual in-line fuses for each power circuit to provide the necessary protection.
1
Positive (+) bar
2
Negative (-) bar
3
Circuit breaker
4
Waterproof fuse holder containing a suitably-rated inline fuse must be fitted.
For suitable fuse rating, refer to:
In-line fuse and thermal breaker ratings
.
Important:
Observe the recommended fuse / breaker ratings provided in the product’s documentation,
however be aware that the suitable fuse / breaker rating is dependent on the number of devices
being connected.
Implementation — direct connection to battery
• Where connection to a power distribution panel is not possible , the power cable supplied with
your product may be connected directly to the vessel's battery, via a suitably rated fuse or breaker.
• The power cable supplied with your product may NOT include a separate drain wire. If this is the
case, only the power cable’s red and black wires need to be connected.
• If the power cable is NOT supplied with a fitted inline fuse, you MUST fit a suitably rated fuse or
breaker between the red wire and the battery’s positive terminal.
• Refer to the inline fuse ratings provided in the product’s documentation.
• If you need to extend the length of the power cable supplied with your product, ensure you
observe the dedicated
Power cable extensions
advice provided in the product’s documentation.
41
Содержание axiom 12
Страница 1: ...2020 Raymarine UK Limited 87298 3 Document number 01 2020 Date English en US Installation instructions...
Страница 2: ......
Страница 4: ......
Страница 8: ...8...
Страница 12: ...12...
Страница 52: ...52...
Страница 80: ......
Страница 83: ......
Страница 84: ...FLIR Belgium BVBA Luxemburgstraat 2 2321 Meer Belgium Tel 44 0 1329 246 700 www raymarine com a brand by...