Chapter 2: Installation
23
Type 1 Drive Units/Stern Drive/Constant Running Pump
Cable Length
(Distribution
panel to Course Computer)
Cable Gauge
Copper Area
Up to 3m (10ft)
12 AWG
2.5 mm
Up to 5m (16ft)
10 AWG
4 mm
Up to 7m (23ft)
8 AWG
6 mm
Up to 10m (32ft)
6 AWG
10 mm
Up to 16m (52ft)
4 AWG
16 mm
81004-01
Type 2 Drive Units (12V)
Cable Length
(Distribution
panel to Course Computer)
Cable Gauge
Copper Area
Up to 5m (16ft)
8 AWG
6 mm
Up to 7m (23ft)
6 AWG
10 mm
Up to 16m (52ft)
4 AWG
16 mm
81004-02
Type 2 Drive Units (24V)
Cable Length
(Distribution
panel to Course Computer)
Cable Gauge
Copper Area
Up to 3m (10ft)
12 AWG
2.5 mm
Up to 5m (16ft)
10 AWG
4 mm
Up to 7m (23ft)
8 AWG
6 mm
Up to 10m (32ft)
6 AWG
10 mm
Up to 16m (52ft)
4 AWG
16 mm
81004-01