Table 9 Interface Commands
Code
Description
Examples
ABF
Aiming Beam OFF
Sent
:
“ABF”
Response
:
“ABF”
ABN
Aiming Beam ON
Sent
:
“ABN”
Response
:
“ABN”
DEABC
Disable External Aiming Beam Control
Sent
:
“DEABC”
Response
:
“DEABC”
DEC
Disable External Control– Disables the external control input
Sent
:
“DEC”
Response
:
“DEC”
DGM
Disable Gate Mode– Disables internal pulse generator.
Sent
:
“DGM”
Response
:
“DGM”
DLE
Disable Hardware Emission Control
Sent
:
“DLE”
Response
:
“DLE”
DMOD
Disable Modulation— Disables the modulation control input.
Sent
:
“DMOD”
Response
:
“DMOD”
DPM
Disable Pulse Mode
Sent
:
“DPM”
Response
:
“DPM
EEABC
Enable External Aiming Beam Control
Sent
:
“EEABC”
Response
:
“EEABC”
EEC
Enable External Control– Enables the external control input.
Sent
:
:
“EEC”
Response
:
“EEC”
EGM
Enable Gate Mode—Enables internal pulse generator gated by
signal applied to modulation input.
Sent
:
“EGM”
Response
:
“EGM”
ELE
Enable Hardware Emission Control
Sent
:
“ELE”
Response
:
“ELE”
EMOD
Enable Modulation— Enables the modulation control input.
Sent
:
“EMOD”
Response
:
“EMOD”
EMOFF
Stop Emission— Stops emission.
Sent
:
“EMOFF”
Response
:
“EMOFF
EMON
Start Emission— Starts emission.
Sent
:
“EMON”
Response
:
“EMON”
EPM
Enable Pulse Mode
Sent
:
“EPM”
Response
:
“EPM”
RBT
Read Board Temperature— Reads the temperature of the laser's
control board. The response is an echo of the command, a
delimiter of “:” and the temperature in degrees centigrade.
Sent
:
“RBT”
Response
:
“RBT:36.6”
RCS
Read Current Setpoint—Reads the setpoint for the LD current.
The response is the command echoed back, followed by a
delimiter of “:”, and then the current setpoint in %.
Sent
:
“RCS”
Response
:
“RCS:56.7”
(Indicates that the LD current
setpoint is 56.7%)