Safety Information 

 
Please read this instruction  carefully and familiarize yourself with  the information we have 

provided before you use the product. In this brochure, important operation procedures, safety and 

other information are provided for you and all future users. In order to ensure operating  safely 

and optimal performance of the product, please do according to following warnings, cautions and 

other information. 

 

Raycus pulsed fiber laser is classified as a high power Class IV laser device. Before supplying 

the power to the device, please make sure that the correct voltage of 24VDC power source is 

connected and the anode and cathode are right. Failure to connect power source correctly will 

cause damage to the device. 

 

The device emits invisible 1060~1085nm wavelength light with average power 70W

100W. 

Do not expose your eyes or skin to the radiation of the laser. 

 

Do not take apart the device, because there are no replaceable accessories available for users 

to use. Any maintenance can only be proceeded in Raycus. 

 

Do not look into the light output end  directly. Use appropriate laser safety eyewear when 

operating the device. 

 

Safety labels and locations 

     

 

The two  labels above  are  located on the  top  of the cover of the device, representing laser 

radicalization. 

 

 

Содержание RFL-P70Q

Страница 1: ...RFL P70Q P100Q 9 RFL P70Q P100Q...

Страница 2: ...ium Pulsed Fiber Laser RFL P70Q P100Q Ver 2 0 Ytterbium Pulsed Fiber Laser User s Guide RFL P70Q P100Q Wuhan Raycus Fiber Laser Technologies Co Ltd 2018 Proprietary information All rights reserved Iss...

Страница 3: ...re supplying the power to the device please make sure that the correct voltage of 24VDC power source is connected and the anode and cathode are right Failure to connect power source correctly will cau...

Страница 4: ...al requirements and cautions 1 1 4 Specifications 2 2 Mounting 3 2 1 Mounting dimensions 3 2 2 Method of installation 3 3 Control Interface 5 4 Operation Regulations 8 4 1 Pre inspection 8 4 2 Operati...

Страница 5: ...y Remark Fiber Laser module 1 1 3 Environmental requirements and cautions Pulsed laser should be driven by 24VDC 1V power source 1 Caution Make sure the corresponding wires of the device are properly...

Страница 6: ...ut please stop marking at once to avoid further damage of the device 10 Power source sudden interruption will do great harm to the laser device Please make sure the power supply works continuously 1 4...

Страница 7: ...Unit mm 2 Isolated output head dimensions As shown in Fig 2 Figure 2 Dimension drawing of output isolator Unit mm 2 2 Method of installation 1 Fix the module stable to the bracket and keep the laser...

Страница 8: ...tches the laser and the control cable is well connected to the laser s interface The recommended electrical connection is shown in Fig 4 User s cont rolle r DB25 Controller interface Power supply wire...

Страница 9: ...imum bit and D7 is maximum bit Range 0 255 hexadecimal 0X00 0XFF 10 13 15 24 25 Ground Digital GND 11 12 16 21 Laser alarms status See alarm codes in table 5 17 VCC 5VDC power supply input for indepen...

Страница 10: ...s be high These pins indicate the following device states Table 5 Definition of alarm signal PIN 12 PIN 11 PIN 16 PIN 21 Alarm item Low Low Low Temperature alarm Low Low High Normal Low High Low Oblig...

Страница 11: ...als are less than 3 mA The connection circuit of input and output signals is shown in Figure 6 Figure 6 Schematic of input and output signals 6 The control board and laser driver can be powered separa...

Страница 12: ...z For model P100Q the frequency setting range is from 20 kHz to 200 kHz 3 Laser marking checking For the device initial testing first turn the power down to zero without turning on the marking system...

Страница 13: ...cessive use or not following the instructions caused by those who are not from Raycus Customer has the responsibility to understand and follow this instruction to use the device Any damage caused by f...

Отзывы: