Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C100~RFL-C2000S
39
4.7.6
Red light to control
Turn the key switch to the "REM" or "ON" position and power up the laser
,
“POWER”
green indicator light is on and the red guide light is output.
The red guide light is off when
“LASER” button in front panel is pressed or command “EMON” is sent via RS-232, while the
red light is on when “LASER” is released or command “EMOFF” is sent via RS-232.
CAUTION: The red light and the laser emission cannot be output at the
same time. If there is no red light output, please check if the "LASER"
button is released and command “EMOFF” is sent.
4.8
Steps of shutting down
Please turn off the laser in the order below:
1)
Turn off the emission;
2)
Turn the key switch to the "OFF" position and release “LASER” button;
3)
Turn off the chiller;
4)
If the product have air conditioner please waiting 10 minutes for the air conditioner to
continue working. If the laser does not have air conditioner, please ignore this step;
5)
Disconnect the air switch;
6)
Cover the output head protection cap;