Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C100~RFL-C2000S
20
Additive to the liquid: satisfies the requirements of PH value and size of solid residual
practicals as above;
Radius of the bending of the armored pipe: off-work state (i.e. transportation and
reservation): minimum radius of bending >= 20 cm; in-work state: minimum radius of
bending >= 30 cm;
Long-term vibration < 2 G; Impact action < 10 G.
4)
Other requirements for chiller:
When starting the cooling system for the first time, check the entire water system and
the joint for water leakage. The external water pipe must be installed and connected according to
the inlet (IN) and outlet (OUT) by the laser. Otherwise, the laser may not work properly.
If you will not use the laser for a long time, water must be emptied from the product,
and then both the inlet and outlet must be blocked with the nuts we provide. Failure to do so may
lead to permanent equipment damage.
CAUTION:
Please set the water temperature in strictly accordance with
the requirements above. Too low temperature may lead to condensation on
the laser module and the output cable. This can cause serious damage to
the equipment.
CAUTION:
Make sure that the water temperature reaches the set point
and the cooling system is working well before you start the laser.
〖
summer
:
29
±
0.5
℃(
RFL-C100~RFL-C1000
);
25
±
0.5
℃(
RFL-C1500S/C2000S
);
winter
:
25
±
0.5
℃
〗
3.4
Installation Procedure
(1)
Place the product in an appropriate position, immobilize it if necessary;
(2)
Check if the power supply has the correct voltage (See Table 5 for the laser model and
corresponding input voltage ), and the earth line is connected, make sure it is firm and reliable;
(3)
Connect the power cable and control cable to the product when power supply is OFF;
(4)
Insert the water pipes into the inlet and outlet;