background image

Wuhan Raycus Fiber Laser Technologies CO., Ltd.

 

                                                                                                                                                                                              P20QB/P30QB

 Pulsed Fiber Laser User’s Guide V2.1

 

 

 

e)

 

Do  not  install  the  collimating  device  into  the  output  head  when  the  laser  device  is  in 

working   

f)

 

The  device  has  three  cooling  fans  at  the  rear  panel  to  dissipate  heat.  In  order  to 

guarantee  enough  airflow  to  help  giving  heat  off,  there  must  be  a  space  of  at  least 

10cm’s width for airflow in front and rear side  of the device. As the cooling fans are 

working  at  blow  condition,  if  laser  is  mounted  in  a  cabinet  with  fans,  the  direction 

should be same as laser’s fans. 

g)

 

Do not look into the output head of the device directly. Please do wear appropriate laser 

safety eyewear during the time when operating the device. 

h)

 

Make sure the pulse repetition rate higher than 20kHz. 

i)

 

For the longest time without pulse is only 100 us. If there is no pulse output, please stop   

marking at once, to avoid further damage of the device. 

j)

 

Power  source  sudden  interruption  will  do  great  harm  to  the  laser  device.  Please  make 

sure the power supply works continuously. 

1.4.

 

Specifications 

Table 2. P20QB/P30QB pulsed fiber laser specifications 

Pulsed fiber laser 

P20QB 

P30QB 

Wavelength(nm) 

1060~1085 

1060~1085 

Polarization 

Random 

Random 

Optical isolator 

Yes 

Yes 

Nominal average output power (W) 

≥20 

≥30 

Single pulse energy (mJ)   

1@20kHz 

1@30kHz 

Beam quality(M

2

<1.5 

<1.5 

Beam Diameter(mm) 

7±1 

7±1 

Pulse duration(ns) 

90-110@20kHz 

120-150@30kHz 

Pulse repetition rate(kHz) 

20 - 60 

30 - 60 

Output Power Tunability(%) 

10-100 

10-100 

Output Fiber Cable length(m) 

3.0 

3.0 

Working voltage(VDC) 

24±1 

24±1 

Power consumption(W) 

200@20

 

300@20

 

Cooling 

Forced Air Cooled 

Forced Air Cooled 

Dimension W×D×H(mm) 

215×286×95 

215×286×95 

Operating temperature(

0

40 

Store temperature(

-20

60 

Operating Humidity(%) 

80% 

 

 

 

Содержание RFL-20QB

Страница 1: ... 内部 A0 会签 阶段 标记 C RFL P20QB 30QB 20QB 30QB 激光器英文说明书 RFL P20QB 30QB JS02 部 门 脉冲激光器技术研究部 编 写 颜鹏晖 20210303 校 对 刘 红 20210305 审 核 李 科 20210305 标 审 李其军 20210305 批 准 黄 保 20210308 武汉锐科光纤激光技术股份有限公司 谢良 夏巨江 旧底图登记号 底图登记号 ...

Страница 2: ...Ytterbium Pulsed Fiber Laser User s Guide RFL P20QB P30QB Wuhan Raycus Fiber Laser Technologies Co Ltd 2021 ...

Страница 3: ...er device Before supplying the power to the device please make sure that the correct voltage of 24V DC power source is connected and the anode and cathode are right Failure to connect power source correctly will cause damage to the device b The device emits invisible 1060 1085nm wavelength light with average power 20W 30W Do not expose your eyes or skin to the radiation of the laser c Do not take ...

Страница 4: ...1 3 Environmental requirements and cautions 1 1 4 Specifications 2 2 Mounting 3 2 1 Mounting dimensions 3 2 2 Method of installation 3 3 Control Interface 5 4 Operation Regulations 7 4 1 Pre inspection 7 4 2 Operation procedures 7 4 3 Cautions 8 5 Instructions for warranty return and maintenance 8 5 1 General warranty 8 5 2 Limitations of warranty 8 5 3 Service and repairs 8 ...

Страница 5: ...e 1 2 Actual configuration list Table 1 Configuration list Items Quantity Remark Fiber Lasermodule 1 1 3 Environmental requirements and cautions Pulsed laser should be driven by 24VDC 1V power source a Caution Make sure the corresponding wires of the device are properly grounded b All the maintenance to the device should only be done by Raycus because there is no replacement or accessory provided ...

Страница 6: ...i For the longest time without pulse is only 100 us If there is no pulse output please stop marking at once to avoid further damage of the device j Power source sudden interruption will do great harm to the laser device Please make sure the power supply works continuously 1 4 Specifications Table 2 P20QB P30QB pulsed fiber laser specifications Pulsed fiber laser P20QB P30QB Wavelength nm 1060 1085...

Страница 7: ...m 2 2 Method of installation a The laser output fiber is the key but very sensitive component During the package transport and operation the bending radius of output fiber must not exceed 15 cm or the laser may be damaged The leading and tail parts of the output fiber must not be excessively bended in case of damaging When returning the laser for warranty it suggests using the original package If ...

Страница 8: ...t A2 P24V Black 24 V power supply negative input forboth laser driver and control board 1 3 4 2 C24V Red 24 V control board power supply positive input 5 PE Yellow green GND d Pin A1 A2 are the positive and negative power line connector to the control board Pin 2 A2 are the positive and negative power line connector to the laser driver During the operation all the power connectors must be correctl...

Страница 9: ...d Digital GND 11 12 16 21 Laser alarms status See alarm codes in Table 4 17 VCC 5V DC power supply input providing power for inside chips of DB25 to ensure that the input and output signals are valid Input current 20mA 18 EE Emission Enable EE signal HIGH Emission Enable LOW or disconnected Emission Disable 19 EM Emission Modulation EM input HIGH 3V Emission ON LOW or disconnected 1V Emission OFF ...

Страница 10: ... system Input voltage 3V 5V are defined as digital High below 1 7V are defined as digital Low d Alarm setting Pins 11 12 16 and 21 are the alarm and status outputs which driven by 5V power from Pin 17 Pin 12 is reserved always be high These pins indicate the following device states Table 6 Definition of alarm states PIN 12 PIN 11 PIN 16 PIN 21 Alarm item Low Low Low Temperature alarm Low Low High ...

Страница 11: ... 4 Operation Regulations 4 1 Pre inspection a Make sure the device appearance is in good condition and the output fiber is neitherexcessively bended nor broken b Make sure signal line of laser and marking system are properly connected 4 2 Operation procedures a Starting procedures Please make sure the control system is on before you turn on the fiber laser Only after at least 1 minute since the po...

Страница 12: ...cus reserves the right to issue a credit note for any defective products produced in normal conditions 5 2 Limitations of warranty The warranty does not cover the maintenance or reimbursement of our product of which the problem results from tampering disassembling misuse accident modification unsuitable physical or operating environment improper maintenance damages due to excessive use or not foll...

Страница 13: ...er If any damage happens to the product please notify the carrier in document immediately All the items about warranty and service above provided by Raycus are only for reference formal contents about warranty and service are subject to the contract Wuhan Raycus Fiber Laser Technologies Co Ltd All Rights Recerved ...

Отзывы: