4.7
Operation Start-ups Sequences
a)
Turn on the water cooler, check whether the water pipe is leaking. Turn off the water cooler and
connect electrically.
b)
Make sure the circuit breaker is in “OFF” position and the “Emergence Stop” button of the front
panel is pressed down. All electrical connections must be completed before the laser is powered on;
c)
Confirm that the three-phase electrical connection iscorrect and the power supply meets the
specifications, turn on the water cooler.
d)
Close the rear panel circuit breaker, release the laser front panel emergency stop switch; ensure that
all laser doors are closed, optical cable fiber delivery connector has been inserted into the laser
processing head (or corresponding equipment), all interlock interfaces have been closed;
e)
Select the required control mode according to 1.4 “control mode”, turn on the key switch, start the
main power supply waiting for the laser to be “Ready” state. When the laser is ready, the tricolor
status lamp on the top the laser lights green, representing that the laser is ready for emitting the laser
beam.
NOTE:
a)
Raycus high power continuous wave lasers are equipped with relative individual backpack air
conditioner, turn on the switch, the air conditioning will then begin to work.
b)
When the working environment temperature and relative humidity of the laser are in the dew point
area (Blue), please let the air conditioner work for 30 minutes before operating the laser.