4.4.8.2
Bypass / Rigging operation
(Using the Bridging and Range limiting box)
(Refer to section 4.4.8 of this manual)
Reset button:
Press and release the Reset button to cancel the override.
Override Key Switch
General override:
Turn the override key switch to the ‘‘Indicator
override’’ position and release
for a complete override. The override indicator will be activated.
Range Limiting Key Switch
Normal Run position:
Normal mode. The system works without a programmed limit.
Slew Range Set position:
This switch position allows access to the Range-limiting mode (refer to section
4.6 of this manual).
Tracks stopped position:
This switch position locks the machine tracks
in place to stop it from moving when one or several limits have been pro-
grammed in the system.
This added safety feature is available in option.
37
Telescopic Cranes Pressure Sensing
Instruction Manual
i3500 Operation