55M3500MNE rev. E
Telescopic cranes with derrick pressure sensors Calibration Manual i3500
8
“p1” and “p2" values indicate the state of proximity sensors (prox1 and prox2). “p1” and
“p2” are used to detect target for the rope direction sensor option, this option is not
available for the telescopic crane pressure sensing, multi-point version.
To know the software version of a pressure sensor or it’s calibration state, press “
”
when “load1” is underlined. The displayed Information will look similar to this:
load 1
---------------------------------------------------------------------
ver:
1.00 07may07
offset :
373
scale :
0.142113
The line beginning with “ver” indicates the software version of the pressure sensor and
its creation date. The next two lines indicate if a sensor has been calibrated or if the
calibration is valid. The ‘scale’ value must be smaller than 1.0.
Relay:
The displayed Information will look similar to this:
relay
inputs
relay
1
2
3
4
5
6
7
8
1
2
3
4
------------------------------------------------------------------------------------------------------------
card 1
1
1
1
1
0
1
1
1
1
1
1
1
The information shown for the relay cards is divided into two blocks:
“Relay” block represents the individual state of every relay. “0” indicates that the
relay coil is energized whereas “1” indicates that it is not energized.
“Inputs” block represents the state of the 4 DIN inputs. A “0” represents an active
input.
A maximum of 4 relay cards can be installed.
Press “
” when card 1 is highlighted to view the software version of a relay card.
The displayed Information will look similar to this:
relay card 1
---------------------------------------------------------------------
ver:
1.00 02may07
The “ver” line indicates the software version of the relay card and its creation date.