background image

 

 

 
 
 

Carefully remove the appliance from the box. 
Prior  to  installing  the  appliance,  test  to  make  sure  the  appliance  operates  properly  by 
plugging the power supply cord into a conveniently located 230V electrical socket. 
Test  all  aspects  of  its  operation  (manual  switches,  remote  and  heater)  to  make  sure  all 

components operate correctly. 

As with most electronic devices, your new electric fireplace has been designed to operate at 
temperatures  between  5

℃ 

and  3

5

.  During  the  cold  winter  months,  allow  the  fireplace  to 

reach room temperature before turning it on.

 

NOTE:There  maybe  trace  of  odor  during  the  first  few  minutes  of  initial  use.This  is 
harmless, normal and will never occur again.

 

 

 
 

 

 

 

Plan where to locate and frame the fireplace. This will save time and money later when you 
install the fireplace. Before installation consider the following: 
1.  Where the fireplace is located must allow for wall and ceiling clearances. 
2.  Consider a location where the fireplace screen will not be exposed to direct sunlight from 

windows or doors. 

3.     

The  appliance  must  be  wired  into  a  separate  single  phase  power  supply  230V~50Hz, 

13amp fused spur. The fused spur/socket must be accessible at all times and must not 
be placed behind the unit. The mains socket must be accessible to ensure the appliance 
can be safely disconnected when required. 

4.   

On built in units the connection must be made using a 13 amp switched fused spur, the 

switch  must  be  accessible  at  all  times,  to  connect  to  a  fused  spur  trim  the  power  cord 
provided. 

WARNING – ELECTRIC SHOCK HAZARD 

It  is  the  customers  responsibility  to  contact  a  qualified 

electrical installer to make sure the electrical installation 

is adequate and in conformance with the regulations. 

Take  special  care  when  cutting  holes  in  walls  or  floor. 

Electrical wires may be behind the wall or floor covering 

and could cause an electrical shock if you touch them. 

Locate any electrical circuits that could be affected by the 

installation of this product and disconnect power circuit. 

 

 
 

 

 

WARNING: THIS APPLIANCE MUST BE EARTHED. 

DO NOT use an extension lead with this appliance. 

The  appliance  is  designed  for  the  voltage  stated  on  the 

data plate. 

Recommended  but  not  mandatory  to  fit  an  individual 

Residual  Current  Device  (RCD)  to  the  cooker  supply 

circuit. 

Hand  this  Manual  to  the  User  for  retention  and  instruct 

in the safe operation of the appliance. 

UNPACKING AND TESTING APPLIANCE

LOCATING THE FIREPLACE

Содержание STRATUS 100-30 XS

Страница 1: ...in these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance INSTALLATION AND OPERATION INSTRUCTIONS FOR STRATUS 100 30 XS STRATUS 125 30 XS STRATUS 75 30 XS ...

Страница 2: ...endable and enjoyable service from your Rayburn product IMPORTANT INSTRUCTIONS 3 UNPACKING AND TESTING APPLIANCE 5 LOCATING THE FIREPLACE 5 STRATUS 100 30 XS 7 STRATUS 125 30 XS 8 SAFETY DRILL SCREW AREA 9 MEDIA OPTIONS 17 OPERATION 18 CARE AND MAINTENANCE 22 REPLACEMENT PARTS 23 WIRING DIAGRAM 25 TROUBLE SHOOTING 26 SERVICE HISTORY 27 WARRANTY 28 INSTALLATION 10 INSTALLATION BUILT IN 10 INSTALLAT...

Страница 3: ... 13 Always use properly grounded fused and polarized outlets 14 Always use ground fault protection where it is required by electrical codes 15 Always disconnect the power before performing any cleaning maintenance or relocation of the heater 16 To prevent a possible fire do not burn wood or other materials in this heater 17 To prevent electric shock or fire always use a certified electrician shoul...

Страница 4: ...ured to prevent it from being tipped over Always use a fire guard when young children and infirm persons can come into contact with the heater Don ts Never leave children unsupervised in a room where the heater is ON and unguarded Never obstruct or cover the fan outlet or force items into heater openings Never use aerosols or steam cleaners on or around the heater Never route the mains supply cabl...

Страница 5: ...Hz 13amp fused spur The fused spur socket must be accessible at all times and must not be placed behind the unit The mains socket must be accessible to ensure the appliance can be safely disconnected when required 4 On built in units the connection must be made using a 13 amp switched fused spur the switch must be accessible at all times to connect to a fused spur trim the power cord provided WARN...

Страница 6: ...is appliance has been tested in accordance with the EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 30 2009 A11 2012 EN 62233 2008 If you need assistance during installation please contact your local dealer NOTE The complete installation must be done in accordance with current Standards and Local Codes The instructions in this manual must be followed to ensure safe operation of the appliance It shoul...

Страница 7: ...his appliance has been tested in accordance with the EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 30 2009 A11 2012 EN 62233 2008 If you need assistance during installation please contact your local dealer NOTE The complete installation must be done in accordance with current Standards and Local Codes The instructions in this manual must be followed to ensure safe operation of the appliance It shou...

Страница 8: ...s appliance has been tested in accordance with the EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 30 2009 A11 2012 EN 62233 2008 If you need assistance during installation please contact your local dealer NOTE The complete installation must be done in accordance with current Standards and Local Codes The instructions in this manual must be followed to ensure safe operation of the appliance It should...

Страница 9: ...9 SAFETY DRILL SCREW AREA There is a safety drill screw area as show below Please make sure that the fix screws are in this area The manual control pad position Safety drill screw area Dark area ...

Страница 10: ...ls are designed to be either built in or wall mounted depending on preference These units allow for the finishing material drywall stone tile etc to be built right down to the glass edge However should that application not be desirable or available the included surround can be used as an alternate finish option Note The optional steel surround is not firmly attached and can be removed from the uni...

Страница 11: ...11 2 Remove the optional trim from the unit as illustrated below Remove the wall framing plates from the unit 3 Re attach the framing plates to the unit as shown below ...

Страница 12: ...12 4 Bend the framing plates as shown 5 Lift the unit into the wall opening Note Two people are required ...

Страница 13: ... mounting screws through the flaming plates securing the unit into the wall studs 7 Using desired materials finish to the glass for a clean face installation OR re attach the steel surround that was removed in STEP 1 ...

Страница 14: ... the back of the fireplace by removing screws Select a location for the hanger to be fixed that is not prone to moisture and is located at least 0 91 m or 3 feet away from combustible materials such as curtains drapes furniture bedding paper etc Before drill check the wall to ensure there is no wiring pipe wires etc in the area Drill 8 or more holes 8mm diameter 40mm depth using a suitable size dr...

Страница 15: ...15 3 Fix the hanger onto the wall and put the fireplace on ...

Страница 16: ...16 4 Fix a bracket beneath the fireplace to ensure the fireplace won t move ...

Страница 17: ...rmiculite decorative media Unplug the unit from the power and make sure it is switched off Unscrew the adjustable screws to take off the front glass Pour the fire glass media into the try Feel free to use any combination of fire glass media that you find most appealing Put back the front glass after you finish the fire glass decoration Vermiculite ...

Страница 18: ...e third time the heating element turns off indicator extinguishes Note after the heating elements are turned on manually the heating elements work but are not controlled by the temperature sensor 2 Press key Press for the first time and the charcoal and flame is in the highest brightness Press for the second time the charcoal and flame is in medium brightness Press for the third time the charcoal ...

Страница 19: ... the remote control will turn off 2 Key flame and charcoal control switch In case of ON press once the flame and the charcoal bed go out the LCD screen does not display Press it again and the flame and the charcoal bed turn on the LCD screen displays The buzzer beeps once when the key is pressed 3 Press 1 to adjust the red flame The buzzer beeps once when the key is pressed 4 Press 2 to adjust the...

Страница 20: ...between 7 and 30 The buzzer beeps when the key is pressed 9 Press shift key Press once the corresponding figure flashes Press now to set current time and week The buzzer does not beep when the key is pressed 10 Press timing parameter setting key Press for the first time and the LCD screen displays to indicate Monday Now the temperature setting flashes press to set the timing temperature for Monday...

Страница 21: ...n displays icon the indicator on the machine lights yellow Press again to turn it off the LCD screen does not display icon and the indicator on the machine goes off The buzzer beeps when the key is pressed After the Open Window function is turned on the program firstly detects if the heating function is turned on If it is turned on the program will save the current ambient temperature value and de...

Страница 22: ...chemes which cater for the recovery and recycling of materials contained within Your co operation is vital to ensure the success of these schemes and for the protection of the environment 1 Switch off and unplug from the power supply before cleaning 2 Using a soft moist cloth with or without a mild soap solution carefully clean the exterior surface of the products CAUTION Allow the product to comp...

Страница 23: ...2184 FLAME EFFECT GLASS 1 6 9 601139B LED LIGHT LED3 23 2 2 0 2 6 9 601140B LED LIGHT LED3 33 2 2 4 4 7 3147504 3133504 3135504 FLICKER ASSEMBLY 1 8 10101221C FLICKER MOTOR 1 10 10702199 10702176 10702178 EMBER BED GLASS PANEL 1 11 10114001B TEMPERATURE SENSOR 1 12 10104002 SWITCH 1 13 301506 REMOTE RECEIVER 1 14 601094F CIRCUIT BOARD 1 15 602083D BLOWER AND HEATER ASSEMBLY FRT45 240 1 16 601035 C...

Страница 24: ...24 EXPLODED VIEW ...

Страница 25: ...Wiring diagram 25 ...

Страница 26: ...ppliance to cool for 10 minutes then turn it on Circuit board is burnt out Inspect the circuit board and replace it if necessary No warm air coming out of appliance Heater is burnt out Inspect the burner and heater assembly and replace it if necessary Flame sputters Flame motor is defective Call a qualified service technician and replace flame motor Remote Control does not work Low batteries Unit ...

Страница 27: ...27 SERVICE HISTORY This heater must be serviced annually depending on usage NOTES Date Dealer Name Service Technician Name Service Performed Special Concerns ...

Страница 28: ...ng your extended warranty period only genuine spare parts must be used in the servicing and maintenance of your stove these spare parts can be ordered via the Premium Retailer directly Consumable items such as glass paint screens bulbs LED boards ceramic fuel effects glass beads and batteries which are either subject to normal wear and tear or parts that require replacement in connection with norm...

Страница 29: ...roduct fault or defect you must inform us within a reasonable amount of time this is within 14 days from the date on which the fault or defect first became apparent If the product fault or defect is notified after 14 days from the date on which the fault or defect became apparent we cannot accept any liability for events or issues which arise after the 14 day period or which are caused or increase...