20
LOCATION
When choosing a location for this appliance you must have:
a.
Sufficient room for the installation (see clearances),
a satisfactory flue (see flue system), and an adequate
air supply for correct combustion and operation (see
Ventilation and Combustion air supply).
b.
Adequate space for maintenance and air circulation.
c.
Solid floor or base of non-combustible material
which is capable of supporting the total weight. (see
Technical Data).
Note: Installation should be carried out in a well ventilated
area.
HEARTH CONSTRUCTION
When a non-combustible floor surface is not available, then
the cooker must be placed on other insulating material. We
recommend a slab of precast concrete 40mm (1½ inches)
deep. If other insulating material is being used, the
dimensions of the slab of this insulating material must afford
similar protection. This hearth must extend 150mm (6 inches)
to either side of the appliances and 225mm (9 inches) to the
front.
ELECTRICAL SUPPLY
All wiring external to the appliance must conform to the
current BS 7671 (U.K.), & Safety Document 635, ETC: Part 1
Section 5.6.4. The Electricity at Work Regulations. The cooker
requires a 230V–240V, 50 Hz supply. Connection of the
appliance and any system controls to the mains supply must
be through a moulded on plug top, (which is fitted with a 5
amp fuse) which is fitted to the appliance in accordance with
EN 60335, Consumer Protection, SI 1994 No. 1768, plug and
sockets etc. (safety) Regulations 1994.
Always install in accordance with current local wiring
regulations.
You should always, when either exposing or working with
wiring, consult a qualified electrician.
n
WARNING: THIS SUPPLY MUST BE EARTHED
(Refer to B.S. 7430: Code for Practice of Earthing)
Where a risk of low voltage can occur, a voltage sensitive
device should be fitted to prevent start-up of the burner so as
not to endanger the installation.
The primary fuse is located in the control box tray.
To isolate the appliance completely unplug from the mains
socket. Always ensure that this socket is easily accessible and
close to the appliance.
Persons in charge of this appliance should be aware of this
socket outlet position.
TO ACCESS THE CONTROL PANEL (
a.
The plinth can be removed by sliding it
approximately 20mm to the left.
b.
Remove the 6 screws which hold the kicker panel in
place.
c.
Remove the 2 retaining screws on either side of the
Control Console.
d.
Carefully withdraw the Control Console, ensuring
that no strains are subjected to the wiring.
e.
Connection to be carried out in accordance with the
Wiring Diagrams (
When bringing your kitchen units up to the sides of the
cooker leave a 10mm gap between the Rayburn and adjacent
units, (see
). Likewise the base of your units can be
brought up flush to the Rayburn’s built-in plinth.
When bringing the work top up to the side of the hob leave a
10mm gap to combustible material (see
).
Worktop
10mm
HOB
Fig. 8.1
Fig. 8.2
8. Installation Process
DESN 517981