![Rayburn Heatranger 216SFW Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/rayburn/heatranger-216sfw/heatranger-216sfw_installation-instructions-manual_789470008.webp)
The Rayburn 216SFW is delivered complete including a
set of boiler removable firebricks where positional
location determines the amount of hot water supplied in
winter and summer seasons.
The oven side and firebox front firebricks are
permanently fixed with fire cement, whilst the two boiler
face side bricks are located for the summer season
thereby providing domestic hot water only. For winter use
or central heating facilities, the boiler face side bricks are
removed. See Fig. 8, 9 + 10. The firebricks fitted to
Rayburn Cookers are of first quality manufacture and
providing the cooker has been installed and used
correctly will have a reasonable life. There are, however,
expendable items and in time will require renewal. The
renewal of firebricks is not major operation and can be
carried out by the average person. The boiler side
firebricks are supported on a frame on the boiler sides
and are held in position by a retaining toggle at the top.
The front plate protection firebrick is held in position by a
retaining rib on the boiler side. The firebricks are not
sealed in with fire cement and can be removed and
refitted quite simply. See Fig. 10.
Replacement bricks either in sets or singly can be
obtained from your Rayburn Stockist. Quote the serial
number which will be found on a brass plate inside the
roasting oven.
GENERAL - FIREBRICK POSITIONS AND
REPLACEMENT
Fig. 8
Summer Use Domestic Hot Water Only
Fig. 10
Firebrick Fitting
8
DESN 510185
Fig. 9
Winter Use Domestic Hot Water Only and Heating
DESN 510186
DESN 510187