(Manufactured by Albion Cylinders) complying with the BS.1566, should be insulated, preferably with not less
than 75mm thick mineral fibre or its equivalent, and fixed vertically as near as possible to the appliance. The
water draw-off pipes to the taps must be dead leg connection from the vent expansion pipe. A drain tap must be
fitted at the lowest point of the system.
A towel rail of not more than 0.55m
2
heating surface may be heated providing the flow and return pipes are not
more than 5m each in length, and provided the cylinder and pipes to the cylinder are insulated.
NOTE:
The appliance
MUST NOT
be operated if the water system is out of operation or has been drained.
Fig.3 Typical Gravity System DESN 511035
Corrosion Inhibitor
A corrosion inhibitor can be used when installing this appliance to an Indirect hot water cylinder only.
If the cylinder is very close to the cooker, a towel rail is advisable as a heat leak and lagging should not be
applied.
Appliance Boiler
The appliance boiler is of stainless steel construction.
INSTALLATION OF APPLIANCE GENERAL
Page 9 of 23