M7 GX Quick Start Guide
7
Raveon Technologies
6. Configuring the M7 GX
6.1.
Overview
There is a “Command Mode” used to program and
configure the
M7 GX
. In the Command Mode, the
M7 GX
modem accepts commands via the serial port and the user
may configure the internal parameters of the unit, such as
frequency and ID codes.
6.2.
Command Mode
The
M7 GX
modem ma
y be put into a “Command Mode”, by
entering a sequence of three plus characters (+++). Using
serial communications software such as
HypterTerminal
,
send the 3-
character command sequence “+++”.
When the
M7 GX
modem first enters the Command Mode, it
sends its model number out its serial port, and then an
“OK”.
6.3.
Setting a Parameter
To set a parameter in the
M7 GX
modem, enter the
Command Mode as described above, then enter the proper
command, a space, the parameter, and then a carriage
return. For Example, to set the destination address of the
M7 GX
modem to 25, enter the following command:
ATDT 25
<CR>.
6.4. CONFIG Button
There is a small push-button inside the
M7
to assist. This
“CONFIG” button may be pressed at any time, and forces
the
M7 GX
into a known state. The CONFIG button is
located inside the
M7 GX
.
The default settings that the
M7 GX
will revert to when the
CONFIG button is pressed are:
1. Serial port 9600 baud, 8 data bits 1 stop, no
parity
2. Serial port flow control is off.