Hard water areas
5.2
DELIVERY
If the. area of installation is recognised as
hard water, it is recommended that a suit-
able water treatment device is installed in
the mains.
5.2.1
The appliance will arrive on site in two
cartons:
The water hardness can be determined by
using the standard test paper or by referring
Local water authority.
DOMESTIC WATER
The domestic hot water must be in accor-
dance with the relevant recommendations
of BS 5546. Copper tubing to BS 2871. 1 is
recommended for water carrying pipework
and MUST be used for pipework carrying
potable water.
Boiler carton containing:
a) boiler fully assembled
b) installation instructions and
user instructions
c) white paper template
d) terminal cover plate (Fig. 12)
g) - 4 coach bolts and wall plugs
- screws and dowels
Valve pack (poly bag):
a) 2-22 mm compression ball valves
(heating)
ELECTRICAL SUPPLY
Warning: this appliance must be earthed
b) l-15 mm compression ball valve
main in boiler box obtaining
c) l-15 mm compression
d) l-15 mm compression outlet
2 15 fibrie washers
2 22 fibrie washers
External wiring to the appliance must be
carried out by a competent person and be
in accordance with the current I.E.E.
Regulations and local regulations which
apply.
The Ravenheat boiler is supplied for con-
nection to a 230 V - 50 Hz single phase
supply.
The supply must be fused at 3 A.
NOTE: The method of connection to the
electricity supply MUST facilitate complete
electrical isolation of the appliance, by the
use of a fused, double pole isolator, having
a contact separation of at least 3 mm in all
poles. The point of connection to the elec-
tricity supply must be readily accessible and
adjacent to the appliance except, where the
appliance is installed in a bathroom, this
MUST be sited outside the bathroom.
Flue box containing (Fig. 12):
Standard Flue Assembly
58 Elbow Header
59 - Flue bend (Fig. 10) item 9
60 -Air intake duct
61 - Flue exhaust duct
62 -Terminal
65 - Pipe centering spring
66 Flue gas sample point
127 -Terminal Cover Plate
SECTION
5
INSTALLATION
5.1
WARNING
5.1 .1
It is MOST IMPORTANT that this appliance
is installed in a VERTICAL POSITION, with
the flue air duct passing through the wall in
a HORIZONTAL PLANE. A minor deviation
from the horizontal is acceptable, provided
that this results in a downward slope of the
flue/air duct away from the combination
boiler.
Fig.
For
vertical flue
system see sect. 5.7.12
(Minimum vertical 1100 mm)
Fig. 12
10
17
Содержание Little Star LS 80
Страница 27: ...Supplied By www heating spares co Tel 0161 620 6677 INSTRUMENT PANEL Fig 50...
Страница 40: ...Supplied By www heating spares co Tel 0161 620 6677 Fig 89 Fig 91 Fig 92 Fig 93 41...
Страница 43: ...Supplied By www heating spares co Tel 0161 620 6677 SECTION 9 ELECTRICAL SYSTEM DIAGRAM Fig 94 44...
Страница 47: ...Supplied By www heating spares co Tel 0161 620 6677 SECTION 1 EXPLODED PARTS DIAGRAM 48...