Close the on/off valves for the central heat-
ing circuit and drain the water from the boil-
er drain point (Fig. 93).
Disconnect the unions 1 and 2 (Fig. 92) slight-
ly turn and remove pipe and auto air vent.
Replace in reverse order, using new seals.
F i l l t h e s y s t e m a s d e s c r i b e d i n t h e
sect. 6.4 & 5 and check for leaks.
TO REMOVE/REPLACE THE PRESSURE
RELIEF VALVE (Fig. 93)
Remove the casing (sect. 7.3).
Close the on/off valves for the heating sys-
tem and drain the water from the drain
point (Fig. 93).
Undo the valve from its body, clean or
replace. Replace in reverse order.
Fill the system as described in (sect. 6.4 &
6.5) and check for leaks.
TO REMOVE/REPLACE TIME CLOCK
(Fig. 88/A)
Remove the casing (sect. 7.3) and lower
the instrument panel (sect. 7.19.1/.3).
Remove control box cover (sect. 7.23.2).
Remove control board (sect. 7.23.2) from
panel.
Remove two clips securing the timer.
Carefully remove the four wires connecting
timer by pulling spade connectors from
timer.
Replace in reverse order (ensure all electrical
connections are made correctly) (Fig. 88/A).
TO REMOVE/REPLACE THE IGNITION
BOARD
Remove casing (sect. 7.3).
Remove the screw from the ignition box
cover.
Detach the ignition box from its base on
the gas valve.
40
Fig. 88
7.32.4
7.32.5
7.33
7.33.1
7.33.3
7.33.4
7.33.5
Remove the PCB cover and detach the
connectors from the board.
Replace in reverse order ensure all electri-
cal connections are made correctly.
TO REMOVE/REPLACE LOW WATER
CUT-OFF SWITCH
Remove the casing (sect. 7.3) and lower
the instrument panel (sect 7.19.1).
Close the on/off valves for the heating
system and drain the water from the drain
point (sect. 5.4.5).
Pull wire off and unscrew the sensor from
its body. Replace in reverse order.
Fill the system as described in the
(sect. 6.4 & 6.5) and check for leaks.
I
EXTERNAL WIRING
Содержание Little Star LS 100
Страница 27: ...Supplied By www heating spares co Tel 0161 620 6677 INSTRUMENT PANEL Fig 50...
Страница 40: ...Supplied By www heating spares co Tel 0161 620 6677 Fig 89 Fig 91 Fig 92 Fig 93 41...
Страница 43: ...Supplied By www heating spares co Tel 0161 620 6677 SECTION 9 ELECTRICAL SYSTEM DIAGRAM Fig 94 44...
Страница 47: ...Supplied By www heating spares co Tel 0161 620 6677 SECTION 1 EXPLODED PARTS DIAGRAM 48...