7.2.6
Inspect the secondary condensate
heat exchanger. Deposits can be
cleared by removing and flushing out
the exchanger Inspect the siphonic
condensate trap for a blockage Any
deposits should be flushed out (Fig. 90)
7.2.6.1
To remove condensate trap (sect. 5.4). Pull
forward the trap (Fig. 90)
Unscrew the earth wire, and the sensor.
Replace in reverse order.
7.2.7
Examine the fan for any mechanical
damage, check to ensure free running of
the fan wheel. Clean the wheel if necessary
with a soft brush. Check sealing gasket
and renew if damaged (sect. 7.6).
7.2.8
Examine flue duct and flue hood and ensure
that there is no obstruction. Examine the
gasket at the entry into the flue duct.
7.2.9
It is essential that a good seal is made at the
outlet to the fan, renew this gasket if there
is any sign of damage or deterioration.
7.3
TO REMOVE/REPLACE THE FRONT
PANEL OF THE CASING (Fig. 19 & 20)
7.3.1
Remove the 2 screws that secure the upper
part of the front panel of the casing.
Lift the front panel few millimeters to the
top, until it is free from the slot and remove
panel
7.4
TO REMOVE/REPLACE THE
COMBUSTION CHAMBER COVER
7.4.1
Remove the front casing panel (sect. 7.3).
7.4.2
Unscrew all the screws that fasten the
cover to the chamber body and put them
into a container so that they don’t get lost.
7.4.3
Detach the cover, being careful not to
damage the seal.
7.4.4
Reassemble in reverse order.
Ensure good seal of cover when
replacing.
7.6
TO REMOVE/REPLACE THE FAN
ASSEMBLY (Fig. 58)
7.6.1
Remove front casing (sect. 7.3).
Remove combustion chamber front cover
as in (sect. 7.4).
7.6.2
Disconnect the electrical connections from
the fan motor.
7.6.4
Support the fan and remove the two fixing
screws and bracket from the front of the flue
hood. Carefully withdraw from condensing
heat
exchanger then from the appliance.
Place in a safe place until required
Reassemble in reverse order. Ensure wires
are connected correctly (Fig. 94)
7.6.5
TO REMOVE/REPLACE CONDENSING
HEAT EXCHANGER FIG. 54-55
7.6.5.1
Remove front casing (sect. 7.3).
Remove combustion chamber front cover
as in (sect 7.4). Remove lower grating by
unscrewing the two screws (Fig. 21).
7.6.5.2
Close the ON/OFF valves for the heating.
Drain the heating system from the drain
point mounted system (Fig. 93).
7.6.5.3
Remove the fan (sect. 7.6)
7.6.5.4
Disconnect 4 unions for the heating water
pipelines (Fig. 54) and remove the two
short pipes.
7.6.5.5
Remove screw holding heat exchanger to
chamber. Disconnect condensing discharge
pipe by pulling off the pushfit connector at
top rear of boiler (Fig. 54).
7.6.5.6
Pull the heat exchanger down and slightly
forward until it comes out of the connection
from chamber (Fig. 55).
7.6.5.7
Replace in reverse order. Taking care to
refit discharge pipe at rear.
IMPORTANT:
When replacing heat
exchanger new seals must be used.
7.7
TO REMOVE/REPLACE THE FLUE HOOD
(FIG. 60)
7.7.1
Remove front casing (sect. 7.3).
Remove combustion chamber front cover
as in (sect. 7.4).
7.7.2
Remove the fan (sect. 7.6)
7.8.11
Remove condensing heat exchanger (sect.
7.6.5)
7.7.3
Remove the three screws on the front that
fasten hood to the combustion chamber.
7.7.4
Remove the two screws at the rear of
hood.
7.7.6
Replace in reverse order
7.8
TO REMOVE THE HEAT EXCHANGER
(FIG. 62-63-64)
7.8.1
Remove front casing (sect 7.3).
Remove combustion chamber front cover
as in (sect. 7;4).
Remove the lower grating (sect.5.4.2)
Lower the instrument panel (sect. 5.4 3 & 4).
32