1.8    PROGRAMMING THE HEATING TIMES  
         (

time clock vers

time clock version only)

         The appliance incorporates a digital clock 
         programmed with a default heating pattern 
         (see table 1); however this can be modi

fi

 ed to 

         suit  individual needs.

         To change the programmed times:

        1. Press and hold the P button for 3 seconds.
        2. Press the up and down arrows to select
            “P TMR” and then press the enter button.
        3. Press the up and down arrows to select the    
            individual day you wish to set, or select the 
            group of days (see table 2) then press the 
            enter button.
        4. Press the up and down arrows to select the           
            ON1 time (

fi

 rst on time) and press the enter 

            button.
        5. Press the up and down arrows to set the 
            OF1 time (

fi

 rst off) and press enter.

            Repeat this process for the remaining 3 
            settings. (Note: if not all 4 times are required  
            then set the remaining on and off times to 
            24.00, this cancels the remaining on and off. 
            For example see the weekend settings in 
            (table 1.)

TABLE 1

TABLE 2

    

  

9

        
        Once the times are set, press the P button and  
        this will return to the main screen.

        NB: If setting the times in a group, the days in 
        the group will all be the same, however days 
        not in this group will remain at the default time. 
       

 For example, setting Mon-Sat 

 For example, setting Mon-Sat will change all 

        these days but Sunday will remain the same as  
        table one unless changed individually.

        The programmed times will only be activated 
        when the boiler is in winter mode (section 1.4 
        key 1) and also set in auto mode (section 1.4 
        key 7). If you wish to override these times, press 
        the timer mode button to select “MAN”, this puts 
        the boiler in manual mode which overrides the 
        timer on the boiler so the heating is on 
        permanently (providing any external controls 
        

fi

 tted are calling for heat). To turn the heating off, 

        press the timer mode button to select off, this 
        will now turn the heating off permanently until 
        either auto or manual is selected.

1.9    DIAGNOSTIC

1.9    DIAGNOSTIC

         The display shows eventual error or faulty 

         The display shows eventual error or faulty 

         message.

         message.

         Stop boiler: The boiler stops the operating cycle             

         Stop boiler: The boiler stops the operating cycle             

         and waits for the disappearance of the cause of 

         and waits for the disappearance of the cause of 

         the error in order to go back to be operating 

         the error in order to go back to be operating 

         mode.

         mode.

         Block boiler: The boiler requires a manual reset 

         Block boiler: The boiler requires a manual reset 

         to become operational again.

         to become operational again.

Содержание CS 80

Страница 1: ...ARTISTS WAY MORLEY LEEDS U K LS27 9ET TEL 0113 252 7007 FAX 0113 238 0229 Website www ravenheat co uk E mail sales ravenheat co uk Instructions for Use Installation and Servicing To be left with the user CS 80 T Natural Gas G20 II 2H3P G C No 4758146 LPG G31 II 2H3P G C No 4758147 CS 90 T Natural Gas G20 II 2H3P G C No 4758148 LPG G31 II 2H3P G C No 4758149 1312 HIGH EFFICIENCY CONDENSING COMBINAT...

Страница 2: ...E CHECKING THE SYSTEM YOUR APPLIANCE CHECKING THE SYSTEM PRESSURE PRESSURE Before lighting the appliance check that the Central Before lighting the appliance check that the Central Heating system pressure is not less than 1 bar If it Heating system pressure is not less than 1 bar If it is below this it will be ecessary to re pressurise the is below this it will be ecessary to re pressurise the sys...

Страница 3: ...rature when the digital display is in hot water or domestic set point temperature Press also to show the boiler values or to show the options program when the digital display is in menu setting 5 Press to set the Central Heating Temperature required when in winter mode Press the arrow up or the arrow down buttons to increase or decrease the temperature 6 Press to set the Domestic Hot Water Tempera...

Страница 4: ...hursday 4 Thursday 5 Friday 5 Friday 6 Saturday 6 Saturday 7 Sunday 7 Sunday 2 Time time clock version only 2 Time time clock version only 3 Central Heating when the appliance 3 Central Heating when the appliance is in central heating mode icon 3 will be is in central heating mode icon 3 will be flashing flashing 4 Auto time clock version only when the 4 Auto time clock version only when the digit...

Страница 5: ...his group will remain at the default time For example setting Mon Sat For example setting Mon Sat will change all these days but Sunday will remain the same as table one unless changed individually The programmed times will only be activated when the boiler is in winter mode section 1 4 key 1 and also set in auto mode section 1 4 key 7 If you wish to override these times press the timer mode butto...

Страница 6: ...elief valve 12 Water pressure transducer 13 CHreturn 14 Controlboard 15 Circulation pump 16 Automaticairvent 17 Condensatedrain 18 Expansionvessel 19 Mainheatexchanger 20 Sparkelectrode 21 Sensingelectrode 22 Fluetemperaturesensor 23 Sparkigniter 24 Fan 25 Burner 26 Manualairvent 27 Overheatcutoffthermostat 28 CHflowsensor 29 CH return sensor 2 0 GENERAL LAYOUT Fig 3 Fig 3 ...

Страница 7: ... electrode 12 Sensor electrode 13 Fan 14 Flue temperature temperature sensor 15 Expansion vessel 16 Automatic air vent 17 Circulation pump 18 Water pressure transducer 19 Safetypressurereliefvalve 20 Diverter valve motor 21 Plate heat exchanger 22 DHW sensor 23 Gasvalve 24 Gasservicecock 25 CHcompressionballvalves 26 DHWflowsensor 27 DHWcompressionballvalves 2 1 OPERATING SCHEME Fig 4 Fig 4 ...

Страница 8: ...ly being for With the summer position only being for domestic hot water domestic hot water The winter position being for central heating The winter position being for central heating with domestic hot water priority with domestic hot water priority 2 3 2 3 DESCRIPTION OF CONTROL SYSTEM DESCRIPTION OF CONTROL SYSTEM AND SEQUENCE OF OPERATION AND SEQUENCE OF OPERATION 2 4 Domestic hot water mode 2 4...

Страница 9: ...e summer position by pressing the Select the summer position by pressing the summer winter button The boiler functions summer winter button The boiler functions like an automatic gas hot water heater like an automatic gas hot water heater When D H W is no longer required the When D H W is no longer required the burner and pump and fan will immediately burner and pump and fan will immediately turn ...

Отзывы: