background image

      

7

1.4  APPLIANCE STATUS INDICATORS

       Your boiler is equipped with a large LCD display     
       that indicates the appliance operating status 
       (

fi

 g. 1).

        After a long period switched off (no power 
        supply), the 

fi

 rst switch on the internal backup 

        circuit will charge in order to

 maintain time 

 maintain time 

        and update parameters. The screen will display 

        and update parameters. The screen will display 

        CLOW, after a few minutes of power su

        CLOW, after a few minutes of power supply the 
        display will be charged enough to allow all the 
        functions. 

     Fig. 1

During the initial charge time, the display doesn’t 
allow the visualisation and/or modi

fi

 cation function 

parameters. Instead other functions are working.
When the appliance operates in rest mode, the 
display shows the boiler temperature and, for the 
time clock version only, the time. Alternatively the 
digital display also shows the water pressure.

       

KEY:

      1 - ON/OFF button.
           Press to turn the boiler ON, “SUM” (hot water
           only) “WIN” (hot water and heating if set) and 
           OFF.
           Press the button also to con

fi

 rm selections.

      2 - Press to reset the appliance if ever an error 
           code is displayed.

   3/4 - Temperature and function mode selectors.
           Press the arrow up or the arrow down to 
           increase or decrease the heating or domestic 
           hot water outlet temperature, when the digital 
           display is in hot water or domestic set-point 
           temperature.
           Press also to show the boiler values or to 
           show the  options program when the digital 
           display is in menu setting.
            
     

 5 - Press to set the Central Heating 

           Temperature required 
           (when in winter mode)

           Press the arrow up or the arrow down buttons 
           to  increase or decrease the temperature.  

     

6 -  Press to set the Domestic Hot Water 

           Temperature required.
           

Press the arrow up or the arrow down buttons 

           to  increase or decrease the temperature. 

      

 

     

7 - TIMER MODE (time clock version only).

           Press to select “Auto” (heating times set), “Manual”
           (heating on all the time) and off (heating off).
 

      

8 - Press to show the boiler values.

           Use the arrow up and arrow down buttons to select 
           the following information:

           PBAR:      water pressure
           SFAN:      speed fan (the display shows 3 digits
                           (e.g. 500 = 5000 rpm)
           TFLOW:   

fl

 ow temperature

           TRET:       return temperature
           TDHW:     domestic hot water temperature
           PWR:       % power of modulation.

         - Press for 3 seconds to enter into menu.
           Use the arrow up or arrow down buttons to select 
           the following options:

         - TIME (time clock version only): It is possible to   
           set the time and the current day (Monday 1, 
           Tuesday 2, Wednesday 3, Thursday 4, Friday 5, 
           Saturday 6, Sunday 7), see section 1.7. 
         - PTMR (only time clock version): It is possible to set 
           the timer, see section 1.8.
         - BOIL: It is possible to set the boiler parameters
                     C.H. max fan speed
                     D.H.W. max fan speed
                     Keep hot: “0” disabled and “1” enabled
                     C.H. High/Low temperature: “1” high/“2” low.

Содержание CS 80

Страница 1: ...ARTISTS WAY MORLEY LEEDS U K LS27 9ET TEL 0113 252 7007 FAX 0113 238 0229 Website www ravenheat co uk E mail sales ravenheat co uk Instructions for Use Installation and Servicing To be left with the user CS 80 T Natural Gas G20 II 2H3P G C No 4758146 LPG G31 II 2H3P G C No 4758147 CS 90 T Natural Gas G20 II 2H3P G C No 4758148 LPG G31 II 2H3P G C No 4758149 1312 HIGH EFFICIENCY CONDENSING COMBINAT...

Страница 2: ...E CHECKING THE SYSTEM YOUR APPLIANCE CHECKING THE SYSTEM PRESSURE PRESSURE Before lighting the appliance check that the Central Before lighting the appliance check that the Central Heating system pressure is not less than 1 bar If it Heating system pressure is not less than 1 bar If it is below this it will be ecessary to re pressurise the is below this it will be ecessary to re pressurise the sys...

Страница 3: ...rature when the digital display is in hot water or domestic set point temperature Press also to show the boiler values or to show the options program when the digital display is in menu setting 5 Press to set the Central Heating Temperature required when in winter mode Press the arrow up or the arrow down buttons to increase or decrease the temperature 6 Press to set the Domestic Hot Water Tempera...

Страница 4: ...hursday 4 Thursday 5 Friday 5 Friday 6 Saturday 6 Saturday 7 Sunday 7 Sunday 2 Time time clock version only 2 Time time clock version only 3 Central Heating when the appliance 3 Central Heating when the appliance is in central heating mode icon 3 will be is in central heating mode icon 3 will be flashing flashing 4 Auto time clock version only when the 4 Auto time clock version only when the digit...

Страница 5: ...his group will remain at the default time For example setting Mon Sat For example setting Mon Sat will change all these days but Sunday will remain the same as table one unless changed individually The programmed times will only be activated when the boiler is in winter mode section 1 4 key 1 and also set in auto mode section 1 4 key 7 If you wish to override these times press the timer mode butto...

Страница 6: ...elief valve 12 Water pressure transducer 13 CHreturn 14 Controlboard 15 Circulation pump 16 Automaticairvent 17 Condensatedrain 18 Expansionvessel 19 Mainheatexchanger 20 Sparkelectrode 21 Sensingelectrode 22 Fluetemperaturesensor 23 Sparkigniter 24 Fan 25 Burner 26 Manualairvent 27 Overheatcutoffthermostat 28 CHflowsensor 29 CH return sensor 2 0 GENERAL LAYOUT Fig 3 Fig 3 ...

Страница 7: ... electrode 12 Sensor electrode 13 Fan 14 Flue temperature temperature sensor 15 Expansion vessel 16 Automatic air vent 17 Circulation pump 18 Water pressure transducer 19 Safetypressurereliefvalve 20 Diverter valve motor 21 Plate heat exchanger 22 DHW sensor 23 Gasvalve 24 Gasservicecock 25 CHcompressionballvalves 26 DHWflowsensor 27 DHWcompressionballvalves 2 1 OPERATING SCHEME Fig 4 Fig 4 ...

Страница 8: ...ly being for With the summer position only being for domestic hot water domestic hot water The winter position being for central heating The winter position being for central heating with domestic hot water priority with domestic hot water priority 2 3 2 3 DESCRIPTION OF CONTROL SYSTEM DESCRIPTION OF CONTROL SYSTEM AND SEQUENCE OF OPERATION AND SEQUENCE OF OPERATION 2 4 Domestic hot water mode 2 4...

Страница 9: ...e summer position by pressing the Select the summer position by pressing the summer winter button The boiler functions summer winter button The boiler functions like an automatic gas hot water heater like an automatic gas hot water heater When D H W is no longer required the When D H W is no longer required the burner and pump and fan will immediately burner and pump and fan will immediately turn ...

Отзывы: