Chapter 3
8
TM-1 Tilt Module Installation & Reference Manual
Current Tilt.
This is a display only. This displays the current tilt angle observed by the TM-1 Tilt Module.
Note:
The maximum tilt angle which the TM-1 may register is ±45° from a level surface.
Calibrate.
On level ground, the current tilt display should read a zero tilt angle. If the display shows a
non-zero tilt angle on known level ground, touch the
Calibrate
button located in the lower, left corner of the Tilt
Configuration screen to recalibrate the TM-1 to a level condition.
Using the Envizio or Envizio Plus
Note:
The Raven Envizio console will require software version 2.0 or newer to properly configure the
TM-1 Tilt Module.
To configure the TM-1 Tilt Module using the Envizio or Envizio Plus:
1.
Touch the
Configuration Pages
button on the Home Page.
2.
From the Configuration Page 1 screen, touch the
Next
button until Configuration Page 5 is displayed.
3.
Touch the
TM-1 Tilt Sensor
button on Configuration Page 5 to display the TM-1 Tilt Sensor page.
The following features and settings may be set from this screen:
Enable TM-1 Tilt.
Select this option to enable the TM-1 Tilt Module and to use tilt corrected GPS messages.
Antenna Height.
To properly adjust the GPS signal for machine tilt, set the height of the GPS antenna above
ground. Review the
section on page 6 for detailed instructions.
Reverse Polarity.
This feature is currently not in use. Set this option to high.
Current Reading.
This is a display only. This displays the current tilt angle observed by the TM-1 Tilt Module.
Note:
The maximum tilt angle which the TM-1 may register is ±45° from a level surface.
Содержание TM-1
Страница 1: ...TM 1 Tilt Module Installation and Reference Manual P N 016 0171 049 Rev E 06 15 E18397 Copyright 2011 ...
Страница 4: ...Table of Contents ii TM 1 Tilt Module Installation Reference Manual ...
Страница 20: ...Chapter 5 16 TM 1 Tilt Module Installation Reference Manual FIGURE 1 TM 1 with Cruizer ...
Страница 21: ...5 Manual No 016 0171 049 17 System Diagrams FIGURE 2 TM 1 with Cruizer SmarTrax and Serial Console ...
Страница 22: ...Chapter 5 18 TM 1 Tilt Module Installation Reference Manual FIGURE 3 TM 1 with Viper Pro and SmarTrax ...
Страница 23: ...5 Manual No 016 0171 049 19 System Diagrams FIGURE 4 TM 1 with Envizio Pro Internal DGPS Receivers ...
Страница 24: ...Chapter 5 20 TM 1 Tilt Module Installation Reference Manual FIGURE 5 TM 1 with Envizio Pro and SmarTrax ...
Страница 25: ...5 Manual No 016 0171 049 21 System Diagrams FIGURE 6 TM 1 with Envizio Plus Lightbar and Raven Console ...
Страница 26: ...Chapter 5 22 TM 1 Tilt Module Installation Reference Manual FIGURE 7 TM 1 with Envizio Plus and SmarTrax ...