P/N 016-0171-277 Rev. L
33
CR7 CALIBRATION AND OPERATION
•
Current Compensation
- Used only with certain non-steering ready machines. This feature is automatically
enabled or disabled during the calibration process and cannot be modified.
•
Anti-Oscillation
- This feature is used only with articulated machines and should not be enabled with any
other type of machine. Anti-Oscillation automatically turns on when an articulated machine is selected during
the machine configuration stage of the SmarTrax setup. Enabling this feature with any machine that is not
articulated may degrade the system performance.
•
Reset SmarTrax
- Resets the SmarTrax system to the default values.
NOTE:
If Reset SmarTrax is selected, the SmarTrax system must be recalibrated before the system can be
enabled. Refer to the Calibrate the SmarTrax System section on page 15 for information on
completing the SmarTrax system calibration.
•
Recal Hydraulics
- Restarts the machine’s steering calibration process. Refer to the Calibrate the Machine’s
Steering System section on page 25 for information on completing the machine’s steering calibration.
•
Raven Service Menu
- Used only for software programming purposes and is not accessible without a code.
DIAGNOSTICS TAB
FIGURE 35. Diagnostics PWM Screen
•
Foot Switch Icon
- Indicates the state of the foot switch. The foot switch image will appear black if there is no
activity, and will turn white if the foot switch is being pressed.
•
Steering Wheel Icon
- Indicates the state of the steering wheel. The steering wheel image will appear black if
there is no activity, and will turn white if the steering wheel is being turned.
•
Left/Right Minimum, Left/Right Maximum
- Displays the SmarTrax valve Minimum and Maximum values.
Adjustment of these values is not typically necessary. Raven Industries recommends leaving these values as
configured by the SmarTrax system unless a technician instructs you to modify the settings.
•
Left/Right Gain
- Displays the Left and Right Gain values. These values cannot be adjusted.
•
Test
- Used to manually test the hydraulic components of the SmarTrax system. To perform a test, select the
desired Test button to steer the machine. If it does not respond as expected, the Minimum or Maximum values
may need to be adjusted.
•
Disengage Sensitivity
- Proper tuning of the Disengage Sensitivity value allows the equipment operator to
disengage SmarTrax by turning the steering wheel with minimal or moderate effort. Disengage Sensitivity
requires minimal adjustment. The default Disengage Sensitivity value when a pressure or flow switch are
present is 150. When one pressure transducer is present in the system, this value represents the PSI value that
must be reached before the system is able to disengage. If two pressure transducers are present, the value
represents the difference between the readings of the transducers.
NOTE:
If the sensitivity value is too low, the steering system may disengage in rougher fields without any
input from the operator. Raising the sensitivity value too high may make disengaging the SmarTrax
system at the steering wheel difficult or impossible.
Содержание SmarTrax
Страница 12: ...CHAPTER 1 6 SmarTrax Calibration Operation Manual ...
Страница 16: ...CHAPTER 2 10 SmarTrax Calibration Operation Manual ...
Страница 42: ...CHAPTER 3 36 SmarTrax Calibration Operation Manual ...
Страница 76: ...CHAPTER 4 70 SmarTrax Calibration Operation Manual ...
Страница 138: ...CHAPTER 6 132 SmarTrax Calibration Operation Manual ...
Страница 148: ...CHAPTER 8 142 SmarTrax Calibration Operation Manual FIGURE 1 SmarTrax 3D with Envizio Pro or Viper Pro and Phoenix 300 ...
Страница 149: ...8 P N 016 0171 277 Rev L 143 SYSTEM DIAGRAMS FIGURE 2 SmarTrax 3D with Envizio Pro or Viper Pro and Phoenix 300 ...
Страница 151: ...8 P N 016 0171 277 Rev L 145 SYSTEM DIAGRAMS FIGURE 4 SmarTrax with Envizio Pro and RGL 600 ...
Страница 152: ...CHAPTER 8 146 SmarTrax Calibration Operation Manual FIGURE 5 Envizio Pro Viper Pro with Slingshot Gen II Cabling ...